Trigger
SCPI Commands :
[SOURce<HW>]:BB:DME:TRIGger:RMODe
[SOURce<HW>]:BB:DME:TRIGger:SLENgth
[SOURce<HW>]:BB:DME:TRIGger:SOURce
[SOURce<HW>]:BB:DME:[TRIGger]:SEQuence
- Commands in total: 12Subgroups: 4Direct child commands: 4
- get_rmode() TrigRunMode[source]
# [SOURce<HW>]:BB:DME:TRIGger:RMODe value: enums.TrigRunMode = driver.source.bb.dme.trigger.get_rmode()
Queries the signal generation status.
- Returns:
run_mode: STOP | RUN
- get_sequence() DmTrigMode[source]
# [SOURce<HW>]:BB:DME:[TRIGger]:SEQuence value: enums.DmTrigMode = driver.source.bb.dme.trigger.get_sequence()
Selects the trigger mode:
AUTO = auto
RETRigger = retrigger
AAUTo = armed auto
ARETrigger = armed retrigger
SINGle = single
- Returns:
trigger_mode: AUTO | RETRigger | AAUTo | ARETrigger | SINGle
- get_slength() int[source]
# [SOURce<HW>]:BB:DME:TRIGger:SLENgth value: int = driver.source.bb.dme.trigger.get_slength()
Defines the length of the signal sequence that is output in the SINGle trigger mode.
- Returns:
seq_length: integer Range: 1 samples to 2^32-1 samples
- get_source() TrigSour[source]
# [SOURce<HW>]:BB:DME:TRIGger:SOURce value: enums.TrigSour = driver.source.bb.dme.trigger.get_source()
Selects the trigger signal source and determines the way the triggering is executed. Provided are:
Internal triggering by a command (INTernal)
External trigger signal via one of the User x connectors EGT1: External global trigger
In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)
EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1
- Returns:
trigger_source: INTernal | EGT1 | EXTernal | BBSY
- set_sequence(trigger_mode: DmTrigMode) None[source]
# [SOURce<HW>]:BB:DME:[TRIGger]:SEQuence driver.source.bb.dme.trigger.set_sequence(trigger_mode = enums.DmTrigMode.AAUTo)
Selects the trigger mode:
AUTO = auto
RETRigger = retrigger
AAUTo = armed auto
ARETrigger = armed retrigger
SINGle = single
- Parameters:
trigger_mode – AUTO | RETRigger | AAUTo | ARETrigger | SINGle
- set_slength(seq_length: int) None[source]
# [SOURce<HW>]:BB:DME:TRIGger:SLENgth driver.source.bb.dme.trigger.set_slength(seq_length = 1)
Defines the length of the signal sequence that is output in the SINGle trigger mode.
- Parameters:
seq_length – integer Range: 1 samples to 2^32-1 samples
- set_source(trigger_source: TrigSour) None[source]
# [SOURce<HW>]:BB:DME:TRIGger:SOURce driver.source.bb.dme.trigger.set_source(trigger_source = enums.TrigSour.BBSY)
Selects the trigger signal source and determines the way the triggering is executed. Provided are:
Internal triggering by a command (INTernal)
External trigger signal via one of the User x connectors EGT1: External global trigger
In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)
EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1
- Parameters:
trigger_source – INTernal | EGT1 | EXTernal | BBSY
Cloning the Group
# Create a copy of the original group, that exists independently
trigger_copy = driver.source.bb.dme.trigger.clone()
Subgroups