Trigger

SCPI Commands :

[SOURce<HW>]:BB:DME:TRIGger:RMODe
[SOURce<HW>]:BB:DME:TRIGger:SLENgth
[SOURce<HW>]:BB:DME:TRIGger:SOURce
[SOURce<HW>]:BB:DME:[TRIGger]:SEQuence
class TriggerCls[source]

Trigger commands group definition. 12 total commands, 4 Subgroups, 4 group commands

get_rmode() RsSmbv.enums.TrigRunMode[source]
# SCPI: [SOURce<HW>]:BB:DME:TRIGger:RMODe
value: enums.TrigRunMode = driver.source.bb.dme.trigger.get_rmode()

Queries the signal generation status.

return

run_mode: STOP| RUN

get_sequence() RsSmbv.enums.DmTrigMode[source]
# SCPI: [SOURce<HW>]:BB:DME:[TRIGger]:SEQuence
value: enums.DmTrigMode = driver.source.bb.dme.trigger.get_sequence()


    INTRO_CMD_HELP: Selects the trigger mode:

    - AUTO = auto
    - RETRigger = retrigger
    - AAUTo = armed auto
    - ARETrigger = armed retrigger
    - SINGle = single

    :return: trigger_mode: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
get_slength() int[source]
# SCPI: [SOURce<HW>]:BB:DME:TRIGger:SLENgth
value: int = driver.source.bb.dme.trigger.get_slength()

Defines the length of the signal sequence that is output in the SINGle trigger mode.

return

seq_length: integer Range: 1 samples to 2^32-1 samples

get_source() RsSmbv.enums.TrigSour[source]
# SCPI: [SOURce<HW>]:BB:DME:TRIGger:SOURce
value: enums.TrigSour = driver.source.bb.dme.trigger.get_source()


    INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are:

    - Internal triggering by a command (INTernal)
    - External trigger signal via one of the User x connectors EGT1: External global trigger
    - In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)
    - EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1

    :return: trigger_source: INTernal| EGT1| EXTernal| BBSY
set_sequence(trigger_mode: RsSmbv.enums.DmTrigMode) None[source]
# SCPI: [SOURce<HW>]:BB:DME:[TRIGger]:SEQuence
driver.source.bb.dme.trigger.set_sequence(trigger_mode = enums.DmTrigMode.AAUTo)


    INTRO_CMD_HELP: Selects the trigger mode:

    - AUTO = auto
    - RETRigger = retrigger
    - AAUTo = armed auto
    - ARETrigger = armed retrigger
    - SINGle = single

    :param trigger_mode: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
set_slength(seq_length: int) None[source]
# SCPI: [SOURce<HW>]:BB:DME:TRIGger:SLENgth
driver.source.bb.dme.trigger.set_slength(seq_length = 1)

Defines the length of the signal sequence that is output in the SINGle trigger mode.

param seq_length

integer Range: 1 samples to 2^32-1 samples

set_source(trigger_source: RsSmbv.enums.TrigSour) None[source]
# SCPI: [SOURce<HW>]:BB:DME:TRIGger:SOURce
driver.source.bb.dme.trigger.set_source(trigger_source = enums.TrigSour.BBSY)


    INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are:

    - Internal triggering by a command (INTernal)
    - External trigger signal via one of the User x connectors EGT1: External global trigger
    - In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)
    - EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1

    :param trigger_source: INTernal| EGT1| EXTernal| BBSY

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.source.bb.dme.trigger.clone()