Efficiency

SCPI Commands :

[SOURce<HW>]:[BB]:DME:EFFiciency:REPLies
[SOURce<HW>]:[BB]:DME:EFFiciency
class EfficiencyCls[source]

Efficiency commands group definition. 2 total commands, 0 Subgroups, 2 group commands

get_replies() RsSmbv.enums.AvionicDmeReplCount[source]
# SCPI: [SOURce<HW>]:[BB]:DME:EFFiciency:REPLies
value: enums.AvionicDmeReplCount = driver.source.bb.dme.efficiency.get_replies()

Sets the number of reply pulses. Use this number to specify absolute values of false or correct pulses during reply efficiency measurements.

return

no_of_replies: 10| 50| 100 10, 50 or 100 reply pulses

get_value() int[source]
# SCPI: [SOURce<HW>]:[BB]:DME:EFFiciency
value: int = driver.source.bb.dme.efficiency.get_value()

Sets the relation between reply pulse pairs and received trigger signals, e.g. with a set efficiency of 50% only every second trigger event leads to the generation of a reply pulse pair.

return

efficiency: integer Range: 0 to 100

set_replies(no_of_replies: RsSmbv.enums.AvionicDmeReplCount) None[source]
# SCPI: [SOURce<HW>]:[BB]:DME:EFFiciency:REPLies
driver.source.bb.dme.efficiency.set_replies(no_of_replies = enums.AvionicDmeReplCount._10)

Sets the number of reply pulses. Use this number to specify absolute values of false or correct pulses during reply efficiency measurements.

param no_of_replies

10| 50| 100 10, 50 or 100 reply pulses

set_value(efficiency: int) None[source]
# SCPI: [SOURce<HW>]:[BB]:DME:EFFiciency
driver.source.bb.dme.efficiency.set_value(efficiency = 1)

Sets the relation between reply pulse pairs and received trigger signals, e.g. with a set efficiency of 50% only every second trigger event leads to the generation of a reply pulse pair.

param efficiency

integer Range: 0 to 100