Hacbook

SCPI Command :

[SOURce<HW>]:BB:NR5G:NODE:CELL<CC(CH0)>:SYINfo:HACBook
class HacbookCls[source]

Hacbook commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(cellNull=CellNull.Default) RsSmbv.enums.AllHarqAckCodebook[source]
# SCPI: [SOURce<HW>]:BB:NR5G:NODE:CELL<CC(CH0)>:SYINfo:HACBook
value: enums.AllHarqAckCodebook = driver.source.bb.nr5G.node.cell.syInfo.hacbook.get(cellNull = repcap.CellNull.Default)

Defines the HARQ ACK reporting according to the PDSCH HARQ ACK codebook.

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

return

harq_ack_codebook: SEMistatic| DYNamic SEMistatic Sets the HARQ ACK reporting according to the PDSCH HARQ ACK codebook to ‘Semi-static’. A UE reports HARQ ACK information for a corresponding PDSCH reception or SPS PDSCH release only in a HARQ ACK codebook that the UE transmits in a slot indicated by a value of a PDSCH-to- HARQ feedback timing indicator field in a corresponding DCI format 1_0 or DCI format 1_1. The UE reports NACK values for HARQ-ACK information bits in an HARQ-ACK codebook that the UE transmits in a slot not indicated by a value of a PDSCH-to-HARQ feedback timing indicator field in a corresponding DCI format 1_0 or DCI format 1_1. DYNamic Sets the HARQ ACK reporting according to the PDSCH HARQ ACK codebook to ‘dynamic’. For a serving cell, an active DL BWP, and an active UL BWP, as described in clause 12, the UE determines a set of occasions for candidate PDSCH receptions for which the UE can transmit corresponding HARQ ACK information in a PUCCH in slot . If serving cell is deactivated, the UE uses as the active DL BWP for determining the set of occasions for candidate PDSCH receptions a DL BWP provided by firstActiveDownlinkBWP-ID.

set(harq_ack_codebook: RsSmbv.enums.AllHarqAckCodebook, cellNull=CellNull.Default) None[source]
# SCPI: [SOURce<HW>]:BB:NR5G:NODE:CELL<CC(CH0)>:SYINfo:HACBook
driver.source.bb.nr5G.node.cell.syInfo.hacbook.set(harq_ack_codebook = enums.AllHarqAckCodebook.DYNamic, cellNull = repcap.CellNull.Default)

Defines the HARQ ACK reporting according to the PDSCH HARQ ACK codebook.

param harq_ack_codebook

SEMistatic| DYNamic SEMistatic Sets the HARQ ACK reporting according to the PDSCH HARQ ACK codebook to ‘Semi-static’. A UE reports HARQ ACK information for a corresponding PDSCH reception or SPS PDSCH release only in a HARQ ACK codebook that the UE transmits in a slot indicated by a value of a PDSCH-to- HARQ feedback timing indicator field in a corresponding DCI format 1_0 or DCI format 1_1. The UE reports NACK values for HARQ-ACK information bits in an HARQ-ACK codebook that the UE transmits in a slot not indicated by a value of a PDSCH-to-HARQ feedback timing indicator field in a corresponding DCI format 1_0 or DCI format 1_1. DYNamic Sets the HARQ ACK reporting according to the PDSCH HARQ ACK codebook to ‘dynamic’. For a serving cell, an active DL BWP, and an active UL BWP, as described in clause 12, the UE determines a set of occasions for candidate PDSCH receptions for which the UE can transmit corresponding HARQ ACK information in a PUCCH in slot . If serving cell is deactivated, the UE uses as the active DL BWP for determining the set of occasions for candidate PDSCH receptions a DL BWP provided by firstActiveDownlinkBWP-ID.

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)