Usage

SCPI Command :

[SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:UL:BWP<BWP(DIR0)>:SRS:RS:SET<GR0>:USAGe
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default, resourceSetNull=ResourceSetNull.Default) SrsRsSetUsageAll[source]
# [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:UL:BWP<BWP(DIR0)>:SRS:RS:SET<GR0>:USAGe
value: enums.SrsRsSetUsageAll = driver.source.bb.nr5G.ubwp.user.cell.uplink.bwp.srs.rs.set.usage.get(userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default, resourceSetNull = repcap.ResourceSetNull.Default)

Queries the type of the SRS transmission.

Parameters:
  • userNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)

  • cellNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

  • bwPartNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)

  • resourceSetNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Set’)

Returns:

srs_rs_set_usage: ASW | BM | CB | NCB NCB = non-codebook based CB = codebook BM = beam management (reserved for futute use) ASW = antenna switching (reserved for futute use)

set(srs_rs_set_usage: SrsRsSetUsageAll, userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default, resourceSetNull=ResourceSetNull.Default) None[source]
# [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:UL:BWP<BWP(DIR0)>:SRS:RS:SET<GR0>:USAGe
driver.source.bb.nr5G.ubwp.user.cell.uplink.bwp.srs.rs.set.usage.set(srs_rs_set_usage = enums.SrsRsSetUsageAll.ASW, userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default, resourceSetNull = repcap.ResourceSetNull.Default)

Queries the type of the SRS transmission.

Parameters:
  • srs_rs_set_usage – ASW | BM | CB | NCB NCB = non-codebook based CB = codebook BM = beam management (reserved for futute use) ASW = antenna switching (reserved for futute use)

  • userNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)

  • cellNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

  • bwPartNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)

  • resourceSetNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Set’)