Bsrs

SCPI Command :

[SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:UL:BWP<BWP(DIR0)>:SRS:RS:SET<GR0>:RES<USER0>:BSRS
class BsrsCls[source]

Bsrs commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default, resourceSetNull=ResourceSetNull.Default, resourceNull=ResourceNull.Default) int[source]
# SCPI: [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:UL:BWP<BWP(DIR0)>:SRS:RS:SET<GR0>:RES<USER0>:BSRS
value: int = driver.source.bb.nr5G.ubwp.user.cell.uplink.bwp.srs.rs.set.res.bsrs.get(userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default, resourceSetNull = repcap.ResourceSetNull.Default, resourceNull = repcap.ResourceNull.Default)

Sets the parameter b-SRS needed to define the length of the SRS sequence.

param userNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

param bwPartNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)

param resourceSetNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Set’)

param resourceNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Res’)

return

srs_rs_bsrs: integer Range: 0 to 3

set(srs_rs_bsrs: int, userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default, resourceSetNull=ResourceSetNull.Default, resourceNull=ResourceNull.Default) None[source]
# SCPI: [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:UL:BWP<BWP(DIR0)>:SRS:RS:SET<GR0>:RES<USER0>:BSRS
driver.source.bb.nr5G.ubwp.user.cell.uplink.bwp.srs.rs.set.res.bsrs.set(srs_rs_bsrs = 1, userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default, resourceSetNull = repcap.ResourceSetNull.Default, resourceNull = repcap.ResourceNull.Default)

Sets the parameter b-SRS needed to define the length of the SRS sequence.

param srs_rs_bsrs

integer Range: 0 to 3

param userNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

param bwPartNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)

param resourceSetNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Set’)

param resourceNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Res’)