HprNumber

SCPI Command :

[SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:PUSCh:HPRNumber
class HprNumberCls[source]

HprNumber commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(cellNull=CellNull.Default, subframeNull=SubframeNull.Default, userNull=UserNull.Default, bwPartNull=BwPartNull.Default, allocationNull=AllocationNull.Default) int[source]
# SCPI: [SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:PUSCh:HPRNumber
value: int = driver.source.bb.nr5G.scheduling.cell.subf.user.bwPart.alloc.pusch.hprNumber.get(cellNull = repcap.CellNull.Default, subframeNull = repcap.SubframeNull.Default, userNull = repcap.UserNull.Default, bwPartNull = repcap.BwPartNull.Default, allocationNull = repcap.AllocationNull.Default)

Sets the HARQ process number for the relevant DCI. Only accessible when the ‘HPN Mode’ is enabled in the ‘Node Settings > Feedback’.

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

param subframeNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)

param userNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)

param bwPartNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘BwPart’)

param allocationNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)

return

process_number: integer Range: 0 to 15 (UL) / 31 (DL)

set(process_number: int, cellNull=CellNull.Default, subframeNull=SubframeNull.Default, userNull=UserNull.Default, bwPartNull=BwPartNull.Default, allocationNull=AllocationNull.Default) None[source]
# SCPI: [SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:PUSCh:HPRNumber
driver.source.bb.nr5G.scheduling.cell.subf.user.bwPart.alloc.pusch.hprNumber.set(process_number = 1, cellNull = repcap.CellNull.Default, subframeNull = repcap.SubframeNull.Default, userNull = repcap.UserNull.Default, bwPartNull = repcap.BwPartNull.Default, allocationNull = repcap.AllocationNull.Default)

Sets the HARQ process number for the relevant DCI. Only accessible when the ‘HPN Mode’ is enabled in the ‘Node Settings > Feedback’.

param process_number

integer Range: 0 to 15 (UL) / 31 (DL)

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

param subframeNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)

param userNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)

param bwPartNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘BwPart’)

param allocationNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)