Trigger

SCPI Commands :

[SOURce<HW>]:BB:EVDO:TRIGger:RMODe
[SOURce<HW>]:BB:EVDO:TRIGger:SLENgth
[SOURce<HW>]:BB:EVDO:TRIGger:SLUNit
[SOURce<HW>]:BB:EVDO:TRIGger:SOURce
[SOURce<HW>]:BB:EVDO:[TRIGger]:SEQuence
Commands in total: 18
Subgroups: 5
Direct child commands: 5
get_rmode() TrigRunMode[source]
# [SOURce<HW>]:BB:EVDO:TRIGger:RMODe
value: enums.TrigRunMode = driver.source.bb.evdo.trigger.get_rmode()

Queries the signal generation status.

Returns:

rmode: STOP | RUN

get_sequence() DmTrigMode[source]
# [SOURce<HW>]:BB:EVDO:[TRIGger]:SEQuence
value: enums.DmTrigMode = driver.source.bb.evdo.trigger.get_sequence()

Selects the trigger mode:

  • AUTO = auto

  • RETRigger = retrigger

  • AAUTo = armed auto

  • ARETrigger = armed retrigger

  • SINGle = single

Returns:

sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle

get_sl_unit() UnitSlEvdo[source]
# [SOURce<HW>]:BB:EVDO:TRIGger:SLUNit
value: enums.UnitSlEvdo = driver.source.bb.evdo.trigger.get_sl_unit()

Defines the unit for the entry of the length of the signal sequence.

Returns:

sl_unit: SLOT | CHIP | SEQuence

get_slength() int[source]
# [SOURce<HW>]:BB:EVDO:TRIGger:SLENgth
value: int = driver.source.bb.evdo.trigger.get_slength()

Defines the length of the signal sequence that is output in the SINGle trigger mode.

Returns:

slength: integer Range: 1 to 4294967295

get_source() TrigSour[source]
# [SOURce<HW>]:BB:EVDO:TRIGger:SOURce
value: enums.TrigSour = driver.source.bb.evdo.trigger.get_source()

Selects the trigger signal source and determines the way the triggering is executed. Provided are:

  • Internal triggering by a command (INTernal)

  • External trigger signal via one of the User x connectors EGT1: External global trigger

  • In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)

  • EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1

Returns:

source: INTernal | EGT1 | EXTernal | BBSY

set_sequence(sequence: DmTrigMode) None[source]
# [SOURce<HW>]:BB:EVDO:[TRIGger]:SEQuence
driver.source.bb.evdo.trigger.set_sequence(sequence = enums.DmTrigMode.AAUTo)

Selects the trigger mode:

  • AUTO = auto

  • RETRigger = retrigger

  • AAUTo = armed auto

  • ARETrigger = armed retrigger

  • SINGle = single

Parameters:

sequence – AUTO | RETRigger | AAUTo | ARETrigger | SINGle

set_sl_unit(sl_unit: UnitSlEvdo) None[source]
# [SOURce<HW>]:BB:EVDO:TRIGger:SLUNit
driver.source.bb.evdo.trigger.set_sl_unit(sl_unit = enums.UnitSlEvdo.CHIP)

Defines the unit for the entry of the length of the signal sequence.

Parameters:

sl_unit – SLOT | CHIP | SEQuence

set_slength(slength: int) None[source]
# [SOURce<HW>]:BB:EVDO:TRIGger:SLENgth
driver.source.bb.evdo.trigger.set_slength(slength = 1)

Defines the length of the signal sequence that is output in the SINGle trigger mode.

Parameters:

slength – integer Range: 1 to 4294967295

set_source(source: TrigSour) None[source]
# [SOURce<HW>]:BB:EVDO:TRIGger:SOURce
driver.source.bb.evdo.trigger.set_source(source = enums.TrigSour.BBSY)

Selects the trigger signal source and determines the way the triggering is executed. Provided are:

  • Internal triggering by a command (INTernal)

  • External trigger signal via one of the User x connectors EGT1: External global trigger

  • In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)

  • EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1

Parameters:

source – INTernal | EGT1 | EXTernal | BBSY

Cloning the Group

# Create a copy of the original group, that exists independently
trigger_copy = driver.source.bb.evdo.trigger.clone()

Subgroups