CycShift

SCPI Command :

[SOURce<HW>]:BB:EUTRa:UL:UE<ST>:[CELL<CCIDX>]:REFSig:SRS:CYCShift
class CycShiftCls[source]

CycShift commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(userEquipment=UserEquipment.Default, cellNull=CellNull.Default) int[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:[CELL<CCIDX>]:REFSig:SRS:CYCShift
value: int = driver.source.bb.eutra.uplink.ue.cell.refsig.srs.cycShift.get(userEquipment = repcap.UserEquipment.Default, cellNull = repcap.CellNull.Default)

Sets the cyclic shift used for the generation of the sounding reference signal CAZAC sequence.

param userEquipment

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

return

cyclic_shift: integer Range: 0 to 11 CyclicShift = 7 to 11 if [:SOURcehw]:BB:EUTRa:UL:UEst[:CELLccidx]:REFSig:SRS[srsidx]:NKTC 4

set(cyclic_shift: int, userEquipment=UserEquipment.Default, cellNull=CellNull.Default) None[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:UL:UE<ST>:[CELL<CCIDX>]:REFSig:SRS:CYCShift
driver.source.bb.eutra.uplink.ue.cell.refsig.srs.cycShift.set(cyclic_shift = 1, userEquipment = repcap.UserEquipment.Default, cellNull = repcap.CellNull.Default)

Sets the cyclic shift used for the generation of the sounding reference signal CAZAC sequence.

param cyclic_shift

integer Range: 0 to 11 CyclicShift = 7 to 11 if [:SOURcehw]:BB:EUTRa:UL:UEst[:CELLccidx]:REFSig:SRS[srsidx]:NKTC 4

param userEquipment

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Ue’)

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)