Trigger
SCPI Commands :
[SOURce<HW>]:BB:EUTRa:TRIGger:RMODe
[SOURce<HW>]:BB:EUTRa:TRIGger:SLENgth
[SOURce<HW>]:BB:EUTRa:TRIGger:SLUNit
[SOURce<HW>]:BB:EUTRa:TRIGger:SOURce
[SOURce<HW>]:BB:EUTRa:[TRIGger]:SEQuence
- class TriggerCls[source]
Trigger commands group definition. 24 total commands, 6 Subgroups, 5 group commands
- get_rmode() RsSmbv.enums.TrigRunMode [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:RMODe value: enums.TrigRunMode = driver.source.bb.eutra.trigger.get_rmode()
Queries the signal generation status.
- return
run_mode: STOP| RUN
- get_sequence() RsSmbv.enums.DmTrigMode [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:[TRIGger]:SEQuence value: enums.DmTrigMode = driver.source.bb.eutra.trigger.get_sequence() INTRO_CMD_HELP: Selects the trigger mode: - AUTO = auto - RETRigger = retrigger - AAUTo = armed auto - ARETrigger = armed retrigger - SINGle = single :return: trigger_mode: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
- get_sl_unit() RsSmbv.enums.EutraUnit [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLUNit value: enums.EutraUnit = driver.source.bb.eutra.trigger.get_sl_unit()
Defines the unit for the entry of the signal sequence length.
- return
seq_len_unit: SEQuence| FRAMe| SUBFrame| SLOT| SAMPle FRAMe A single frame is generated after a trigger event. SEQuence A single sequence is generated after a trigger event. SUBFrame A single subframe is generated after a trigger event. SLOT A single slot is generated after a trigger event. SAMPle Number of samples are generated after a trigger event.
- get_slength() int [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLENgth value: int = driver.source.bb.eutra.trigger.get_slength()
Defines the length of the signal sequence that is output in the SINGle trigger mode.
- return
sequence_length: integer Range: 1 to 4294967295
- get_source() RsSmbv.enums.TrigSour [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SOURce value: enums.TrigSour = driver.source.bb.eutra.trigger.get_source() INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are: - Internal triggering by a command (INTernal) - External trigger signal via one of the User x connectors EGT1: External global trigger - In primary-secondary instrument mode, the external baseband synchronization signal (BBSY) - EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1 :return: source: INTernal| EGT1| EXTernal| BBSY
- set_sequence(trigger_mode: RsSmbv.enums.DmTrigMode) None [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:[TRIGger]:SEQuence driver.source.bb.eutra.trigger.set_sequence(trigger_mode = enums.DmTrigMode.AAUTo) INTRO_CMD_HELP: Selects the trigger mode: - AUTO = auto - RETRigger = retrigger - AAUTo = armed auto - ARETrigger = armed retrigger - SINGle = single :param trigger_mode: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
- set_sl_unit(seq_len_unit: RsSmbv.enums.EutraUnit) None [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLUNit driver.source.bb.eutra.trigger.set_sl_unit(seq_len_unit = enums.EutraUnit.FRAMe)
Defines the unit for the entry of the signal sequence length.
- param seq_len_unit
SEQuence| FRAMe| SUBFrame| SLOT| SAMPle FRAMe A single frame is generated after a trigger event. SEQuence A single sequence is generated after a trigger event. SUBFrame A single subframe is generated after a trigger event. SLOT A single slot is generated after a trigger event. SAMPle Number of samples are generated after a trigger event.
- set_slength(sequence_length: int) None [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLENgth driver.source.bb.eutra.trigger.set_slength(sequence_length = 1)
Defines the length of the signal sequence that is output in the SINGle trigger mode.
- param sequence_length
integer Range: 1 to 4294967295
- set_source(source: RsSmbv.enums.TrigSour) None [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SOURce driver.source.bb.eutra.trigger.set_source(source = enums.TrigSour.BBSY) INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are: - Internal triggering by a command (INTernal) - External trigger signal via one of the User x connectors EGT1: External global trigger - In primary-secondary instrument mode, the external baseband synchronization signal (BBSY) - EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1 :param source: INTernal| EGT1| EXTernal| BBSY
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.source.bb.eutra.trigger.clone()
Subgroups