Mpart
SCPI Command :
[SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:TIMing:DPOWer:MPARt
- class MpartCls[source]
Mpart commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(mobileStation=MobileStation.Default) float [source]
# SCPI: [SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:TIMing:DPOWer:MPARt value: float = driver.source.bb.w3Gpp.mstation.pcpch.timing.dpower.mpart.get(mobileStation = repcap.MobileStation.Default)
Queries the level correction value for the message part. In case of one UE active, the power of the message part can be calculated by adding the set RF level.
- param mobileStation
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)
- return
mpart: float Range: -80 to 0