Trigger

SCPI Commands :

[SOURce<HW>]:BB:WLNN:TRIGger:RMODe
[SOURce<HW>]:BB:WLNN:TRIGger:SLENgth
[SOURce<HW>]:BB:WLNN:TRIGger:SLUNit
[SOURce<HW>]:BB:WLNN:TRIGger:SOURce
[SOURce<HW>]:BB:WLNN:[TRIGger]:SEQuence
class TriggerCls[source]

Trigger commands group definition. 27 total commands, 5 Subgroups, 5 group commands

get_rmode() RsSmbv.enums.TrigRunMode[source]
# SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:RMODe
value: enums.TrigRunMode = driver.source.bb.wlnn.trigger.get_rmode()

The command queries the current status of signal generation for all trigger modes with IEEE 802.11 WLAN modulation on.

return

rmode: RUN| STOP RUN the signal is generated. A trigger event occurred in the triggered mode. STOP the signal is not generated. A trigger event did not occur in the triggered modes, or signal generation was stopped by the command :BB:WLNN:TRIG:ARM:EXECute (armed trigger modes only) .

get_sequence() RsSmbv.enums.DmTrigMode[source]
# SCPI: [SOURce<HW>]:BB:WLNN:[TRIGger]:SEQuence
value: enums.DmTrigMode = driver.source.bb.wlnn.trigger.get_sequence()


    INTRO_CMD_HELP: Selects the trigger mode:

    - AUTO = auto
    - RETRigger = retrigger
    - AAUTo = armed auto
    - ARETrigger = armed retrigger
    - SINGle = single

    :return: sequence: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
get_sl_unit() RsSmbv.enums.UnitSlB[source]
# SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SLUNit
value: enums.UnitSlB = driver.source.bb.wlnn.trigger.get_sl_unit()

Defines the unit for the entry of the length of the signal sequence ([:SOURce<hw>]:BB:WLNN:TRIGger:SLENgth) to be output in the single trigger mode ([:SOURce<hw>]:BB:WLNN[:TRIGger]:SEQuence is set to SINGle) .

return

sl_unit: SAMPle| SEQuence SAMPle Unit Sample. A single sample is generated after a trigger event. SEQuence Unit Sequence Length. A single sequence is generated after a trigger event.

get_slength() int[source]
# SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SLENgth
value: int = driver.source.bb.wlnn.trigger.get_slength()

The command defines the length of the signal sequence to be output in the ‘Single’ trigger mode ([:SOURce<hw>]:BB:WLNN[:TRIGger]:SEQuence is set to SING) . The input is made in terms of samples. It is possible to output deliberately just part of the frame, an exact sequence of the frame, or a defined number of repetitions of the frame.

return

slength: integer Range: 1 to (2^32) - 1, Unit: sample

get_source() RsSmbv.enums.TrigSour[source]
# SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SOURce
value: enums.TrigSour = driver.source.bb.wlnn.trigger.get_source()


    INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are:

    - Internal triggering by a command (INTernal)
    - External trigger signal via one of the User x connectors EGT1: External global trigger
    - In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)
    - EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1

    :return: source: INTernal| EGT1| EXTernal| BBSY
set_sequence(sequence: RsSmbv.enums.DmTrigMode) None[source]
# SCPI: [SOURce<HW>]:BB:WLNN:[TRIGger]:SEQuence
driver.source.bb.wlnn.trigger.set_sequence(sequence = enums.DmTrigMode.AAUTo)


    INTRO_CMD_HELP: Selects the trigger mode:

    - AUTO = auto
    - RETRigger = retrigger
    - AAUTo = armed auto
    - ARETrigger = armed retrigger
    - SINGle = single

    :param sequence: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
set_sl_unit(sl_unit: RsSmbv.enums.UnitSlB) None[source]
# SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SLUNit
driver.source.bb.wlnn.trigger.set_sl_unit(sl_unit = enums.UnitSlB.SAMPle)

Defines the unit for the entry of the length of the signal sequence ([:SOURce<hw>]:BB:WLNN:TRIGger:SLENgth) to be output in the single trigger mode ([:SOURce<hw>]:BB:WLNN[:TRIGger]:SEQuence is set to SINGle) .

param sl_unit

SAMPle| SEQuence SAMPle Unit Sample. A single sample is generated after a trigger event. SEQuence Unit Sequence Length. A single sequence is generated after a trigger event.

set_slength(slength: int) None[source]
# SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SLENgth
driver.source.bb.wlnn.trigger.set_slength(slength = 1)

The command defines the length of the signal sequence to be output in the ‘Single’ trigger mode ([:SOURce<hw>]:BB:WLNN[:TRIGger]:SEQuence is set to SING) . The input is made in terms of samples. It is possible to output deliberately just part of the frame, an exact sequence of the frame, or a defined number of repetitions of the frame.

param slength

integer Range: 1 to (2^32) - 1, Unit: sample

set_source(source: RsSmbv.enums.TrigSour) None[source]
# SCPI: [SOURce<HW>]:BB:WLNN:TRIGger:SOURce
driver.source.bb.wlnn.trigger.set_source(source = enums.TrigSour.BBSY)


    INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are:

    - Internal triggering by a command (INTernal)
    - External trigger signal via one of the User x connectors EGT1: External global trigger
    - In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)
    - EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1

    :param source: INTernal| EGT1| EXTernal| BBSY

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.source.bb.wlnn.trigger.clone()

Subgroups