Read

SCPI Command :

[SOURce<HW>]:BB:TDSCdma:DOWN:CELL<ST>:SLOT<CH0>:CHANnel<US0>:DPCCh:TPC:READ
class ReadCls[source]

Read commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(cell=Cell.Default, slotNull=SlotNull.Default, channelNull=ChannelNull.Default) RsSmbv.enums.TpcReadMode[source]
# SCPI: [SOURce<HW>]:BB:TDSCdma:DOWN:CELL<ST>:SLOT<CH0>:CHANnel<US0>:DPCCh:TPC:READ
value: enums.TpcReadMode = driver.source.bb.tdscdma.down.cell.slot.channel.dpcch.tpc.read.get(cell = repcap.Cell.Default, slotNull = repcap.SlotNull.Default, channelNull = repcap.ChannelNull.Default)

Sets the read out mode for the bit pattern of the TPC field.

param cell

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)

param slotNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Slot’)

param channelNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Channel’)

return

read: CONTinuous| S0A| S1A| S01A| S10A CONTinous The TPC bits are used cyclically. S0A The TPC bits are used once and then the TPC sequence is continued with 0 bits. S1A The TPC bits are used once and then the TPC sequence is continued with 1 bit. S01A The TPC bits are used once and then the TPC sequence is continued with 0 and 1 bits alternately S10A The TPC bits are used once, and then the TPC sequence is continued with 1 and 0 bits alternately

set(read: RsSmbv.enums.TpcReadMode, cell=Cell.Default, slotNull=SlotNull.Default, channelNull=ChannelNull.Default) None[source]
# SCPI: [SOURce<HW>]:BB:TDSCdma:DOWN:CELL<ST>:SLOT<CH0>:CHANnel<US0>:DPCCh:TPC:READ
driver.source.bb.tdscdma.down.cell.slot.channel.dpcch.tpc.read.set(read = enums.TpcReadMode.CONTinuous, cell = repcap.Cell.Default, slotNull = repcap.SlotNull.Default, channelNull = repcap.ChannelNull.Default)

Sets the read out mode for the bit pattern of the TPC field.

param read

CONTinuous| S0A| S1A| S01A| S10A CONTinous The TPC bits are used cyclically. S0A The TPC bits are used once and then the TPC sequence is continued with 0 bits. S1A The TPC bits are used once and then the TPC sequence is continued with 1 bit. S01A The TPC bits are used once and then the TPC sequence is continued with 0 and 1 bits alternately S10A The TPC bits are used once, and then the TPC sequence is continued with 1 and 0 bits alternately

param cell

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)

param slotNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Slot’)

param channelNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Channel’)