RvSequence
SCPI Command :
[SOURce<HW>]:BB:TDSCdma:DOWN:CELL<ST>:ENH:DCH:HSDPA:RVSequence
- class RvSequenceCls[source]
RvSequence commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(cell=Cell.Default) str [source]
# SCPI: [SOURce<HW>]:BB:TDSCdma:DOWN:CELL<ST>:ENH:DCH:HSDPA:RVSequence value: str = driver.source.bb.tdscdma.down.cell.enh.dch.hsdpa.rvSequence.get(cell = repcap.Cell.Default)
For HARQ mode set to constant NACK, sets the retransmission sequence. For HSUPA, the command is a query only.
- param cell
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)
- return
rv_sequence: string of 30 coma-separated values The sequence length determines the maximum number of retransmissions. New data is retrieved from the data source after reaching the end of the sequence.
- set(rv_sequence: str, cell=Cell.Default) None [source]
# SCPI: [SOURce<HW>]:BB:TDSCdma:DOWN:CELL<ST>:ENH:DCH:HSDPA:RVSequence driver.source.bb.tdscdma.down.cell.enh.dch.hsdpa.rvSequence.set(rv_sequence = 'abc', cell = repcap.Cell.Default)
For HARQ mode set to constant NACK, sets the retransmission sequence. For HSUPA, the command is a query only.
- param rv_sequence
string of 30 coma-separated values The sequence length determines the maximum number of retransmissions. New data is retrieved from the data source after reaching the end of the sequence.
- param cell
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)