Trigger

SCPI Commands :

[SOURce<HW>]:BB:GBAS:TRIGger:RMODe
[SOURce<HW>]:BB:GBAS:TRIGger:SLENgth
[SOURce<HW>]:BB:GBAS:TRIGger:SLUNit
[SOURce<HW>]:BB:GBAS:TRIGger:SOURce
[SOURce<HW>]:BB:GBAS:[TRIGger]:SEQuence
Commands in total: 20
Subgroups: 5
Direct child commands: 5
get_rmode() TrigRunMode[source]
# [SOURce<HW>]:BB:GBAS:TRIGger:RMODe
value: enums.TrigRunMode = driver.source.bb.gbas.trigger.get_rmode()

Queries the status of signal generation.

Returns:

rmode: STOP | RUN

get_sequence() DmTrigMode[source]
# [SOURce<HW>]:BB:GBAS:[TRIGger]:SEQuence
value: enums.DmTrigMode = driver.source.bb.gbas.trigger.get_sequence()

Selects the trigger mode.

Returns:

sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle

get_sl_unit() UnitSlB[source]
# [SOURce<HW>]:BB:GBAS:TRIGger:SLUNit
value: enums.UnitSlB = driver.source.bb.gbas.trigger.get_sl_unit()

Sets the units the trigger sequence length is expressed in.

Returns:

sl_unit: SEQuence | SAMPle

get_slength() int[source]
# [SOURce<HW>]:BB:GBAS:TRIGger:SLENgth
value: int = driver.source.bb.gbas.trigger.get_slength()

Defines the signal sequence length.

Returns:

slength: integer Range: 1 to 4294967295

get_source() TriggerSourceB[source]
# [SOURce<HW>]:BB:GBAS:TRIGger:SOURce
value: enums.TriggerSourceB = driver.source.bb.gbas.trigger.get_source()

Selects the trigger signal source and determines the way the triggering is executed. Provided are:

  • Internal triggering by a command (INTernal)

  • External trigger signal via one of the User x connectors EGT1: External global trigger

  • In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)

  • EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1

Returns:

source: INTernal | EGT1 | EXTernal | EGC1 | BBSY

set_sequence(sequence: DmTrigMode) None[source]
# [SOURce<HW>]:BB:GBAS:[TRIGger]:SEQuence
driver.source.bb.gbas.trigger.set_sequence(sequence = enums.DmTrigMode.AAUTo)

Selects the trigger mode.

Parameters:

sequence – AUTO | RETRigger | AAUTo | ARETrigger | SINGle

set_sl_unit(sl_unit: UnitSlB) None[source]
# [SOURce<HW>]:BB:GBAS:TRIGger:SLUNit
driver.source.bb.gbas.trigger.set_sl_unit(sl_unit = enums.UnitSlB.SAMPle)

Sets the units the trigger sequence length is expressed in.

Parameters:

sl_unit – SEQuence | SAMPle

set_slength(slength: int) None[source]
# [SOURce<HW>]:BB:GBAS:TRIGger:SLENgth
driver.source.bb.gbas.trigger.set_slength(slength = 1)

Defines the signal sequence length.

Parameters:

slength – integer Range: 1 to 4294967295

set_source(source: TriggerSourceB) None[source]
# [SOURce<HW>]:BB:GBAS:TRIGger:SOURce
driver.source.bb.gbas.trigger.set_source(source = enums.TriggerSourceB.BEXTernal)

Selects the trigger signal source and determines the way the triggering is executed. Provided are:

  • Internal triggering by a command (INTernal)

  • External trigger signal via one of the User x connectors EGT1: External global trigger

  • In primary-secondary instrument mode, the external baseband synchronization signal (BBSY)

  • EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMBV100B accepts this value and maps it automatically as follows: EXTernal = EGT1

Parameters:

source – INTernal | EGT1 | EXTernal | EGC1 | BBSY

Cloning the Group

# Create a copy of the original group, that exists independently
trigger_copy = driver.source.bb.gbas.trigger.clone()

Subgroups