Data

SCPI Command :

[SOURce<HW>]:BB:EUTRa:DL:[SUBF<ST0>]:ALLoc<CH0>:[CW<USER>]:DATA
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(subframeNull=SubframeNull.Default, allocationNull=AllocationNull.Default, codeword=Codeword.Default) EutraDlDataSourceUser[source]
# [SOURce<HW>]:BB:EUTRa:DL:[SUBF<ST0>]:ALLoc<CH0>:[CW<USER>]:DATA
value: enums.EutraDlDataSourceUser = driver.source.bb.eutra.downlink.subf.alloc.cw.data.get(subframeNull = repcap.SubframeNull.Default, allocationNull = repcap.AllocationNull.Default, codeword = repcap.Codeword.Default)

Sets the data source for the selected allocation. For allocations with two codewords, the data source for the second codeword is automatically set to the data source set for the first one.

Parameters:
  • subframeNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)

  • allocationNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)

  • codeword – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cw’)

Returns:

data: USER1 | USER2 | USER3 | USER4 | PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23 | PATTern | DLISt | ZERO | ONE | MIB | MCCH | MTCH MIB (Result parameter) Indicates that the PBCH transmits real MIB data. (See also method RsSmw.source.bb.eutra.downlink.pbch.mib() ) MCCH | MTCH (Result parameter) Indicates allocations in the MBSFN subframes, if MBSFN is used. (See also method RsSmw.source.bb.eutra.downlink.mbsfn.mode() )

set(data: EutraDlDataSourceUser, subframeNull=SubframeNull.Default, allocationNull=AllocationNull.Default, codeword=Codeword.Default) None[source]
# [SOURce<HW>]:BB:EUTRa:DL:[SUBF<ST0>]:ALLoc<CH0>:[CW<USER>]:DATA
driver.source.bb.eutra.downlink.subf.alloc.cw.data.set(data = enums.EutraDlDataSourceUser.DLISt, subframeNull = repcap.SubframeNull.Default, allocationNull = repcap.AllocationNull.Default, codeword = repcap.Codeword.Default)

Sets the data source for the selected allocation. For allocations with two codewords, the data source for the second codeword is automatically set to the data source set for the first one.

Parameters:
  • data – USER1 | USER2 | USER3 | USER4 | PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23 | PATTern | DLISt | ZERO | ONE | MIB | MCCH | MTCH MIB (Result parameter) Indicates that the PBCH transmits real MIB data. (See also method RsSmw.source.bb.eutra.downlink.pbch.mib() ) MCCH | MTCH (Result parameter) Indicates allocations in the MBSFN subframes, if MBSFN is used. (See also method RsSmw.source.bb.eutra.downlink.mbsfn.mode() )

  • subframeNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)

  • allocationNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)