Trigger

SCPI Commands :

[SOURce<HW>]:BB:EUTRa:TRIGger:RMODe
[SOURce<HW>]:BB:EUTRa:TRIGger:SLENgth
[SOURce<HW>]:BB:EUTRa:TRIGger:SLUNit
[SOURce<HW>]:BB:EUTRa:TRIGger:SOURce
[SOURce<HW>]:BB:EUTRa:[TRIGger]:SEQuence
class TriggerCls[source]

Trigger commands group definition. 28 total commands, 7 Subgroups, 5 group commands

get_rmode() RsSmw.enums.TrigRunMode[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:RMODe
value: enums.TrigRunMode = driver.source.bb.eutra.trigger.get_rmode()

Queries the signal generation status.

return

run_mode: STOP| RUN

get_sequence() RsSmw.enums.DmTrigMode[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:[TRIGger]:SEQuence
value: enums.DmTrigMode = driver.source.bb.eutra.trigger.get_sequence()


    INTRO_CMD_HELP: Selects the trigger mode:

    - AUTO = auto
    - RETRigger = retrigger
    - AAUTo = armed auto
    - ARETrigger = armed retrigger
    - SINGle = single

    :return: trigger_mode: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
get_sl_unit() RsSmw.enums.Unit[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLUNit
value: enums.Unit = driver.source.bb.eutra.trigger.get_sl_unit()

Defines the unit for the entry of the signal sequence length.

return

seq_len_unit: SEQuence| FRAMe| SUBFrame| SLOT| SAMPle FRAMe A single frame is generated after a trigger event. SEQuence A single sequence is generated after a trigger event. SUBFrame A single subframe is generated after a trigger event. SLOT A single slot is generated after a trigger event. SAMPle Number of samples are generated after a trigger event.

get_slength() int[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLENgth
value: int = driver.source.bb.eutra.trigger.get_slength()

Defines the length of the signal sequence that is output in the SINGle trigger mode.

return

sequence_length: integer Range: 1 to 4294967295

get_source() RsSmw.enums.TriggerSourceC[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SOURce
value: enums.TriggerSourceC = driver.source.bb.eutra.trigger.get_source()


    INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are:

    - Internal triggering by a command (INTernal)
    - External trigger signal via one of the local or global connectors
    Table Header:

    - EGT1|EGT2: External global trigger
    - EGC1|EGC2: External global clock
    - ELTRigger: External local trigger
    - ELCLock: External local clock
    - Internal triggering by a signal from the other basebands (INTA|INTB)
    - In primary-secondary instrument mode, the external baseband synchronization
signal (BBSY)
  • OBASeband|BEXTernal|EXTernal: Setting only Provided only for backward

compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)

return

source: INTB| INTernal| OBASeband| EGT1| EGT2| EGC1| EGC2| ELTRigger| INTA| ELCLock| BEXTernal| EXTernal | BBSY

set_sequence(trigger_mode: RsSmw.enums.DmTrigMode) None[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:[TRIGger]:SEQuence
driver.source.bb.eutra.trigger.set_sequence(trigger_mode = enums.DmTrigMode.AAUTo)


    INTRO_CMD_HELP: Selects the trigger mode:

    - AUTO = auto
    - RETRigger = retrigger
    - AAUTo = armed auto
    - ARETrigger = armed retrigger
    - SINGle = single

    :param trigger_mode: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
set_sl_unit(seq_len_unit: RsSmw.enums.Unit) None[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLUNit
driver.source.bb.eutra.trigger.set_sl_unit(seq_len_unit = enums.Unit.FRAMe)

Defines the unit for the entry of the signal sequence length.

param seq_len_unit

SEQuence| FRAMe| SUBFrame| SLOT| SAMPle FRAMe A single frame is generated after a trigger event. SEQuence A single sequence is generated after a trigger event. SUBFrame A single subframe is generated after a trigger event. SLOT A single slot is generated after a trigger event. SAMPle Number of samples are generated after a trigger event.

set_slength(sequence_length: int) None[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLENgth
driver.source.bb.eutra.trigger.set_slength(sequence_length = 1)

Defines the length of the signal sequence that is output in the SINGle trigger mode.

param sequence_length

integer Range: 1 to 4294967295

set_source(source: RsSmw.enums.TriggerSourceC) None[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SOURce
driver.source.bb.eutra.trigger.set_source(source = enums.TriggerSourceC.BBSY)


    INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are:

    - Internal triggering by a command (INTernal)
    - External trigger signal via one of the local or global connectors
    Table Header:

    - EGT1|EGT2: External global trigger
    - EGC1|EGC2: External global clock
    - ELTRigger: External local trigger
    - ELCLock: External local clock
    - Internal triggering by a signal from the other basebands (INTA|INTB)
    - In primary-secondary instrument mode, the external baseband synchronization
signal (BBSY)
  • OBASeband|BEXTernal|EXTernal: Setting only Provided only for backward

compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)

param source

INTB| INTernal| OBASeband| EGT1| EGT2| EGC1| EGC2| ELTRigger| INTA| ELCLock| BEXTernal| EXTernal | BBSY

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.source.bb.eutra.trigger.clone()

Subgroups