RfPower

SCPI Command :

[SENSe]:SWEep:EGATe:LEVel:RFPower
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get() float[source]
# [SENSe]:SWEep:EGATe:LEVel:RFPower
value: float = driver.applications.k14Xnr5G.sense.sweep.egate.level.rfPower.get()

Defines the gate level for which the gate is open. Note that any RF attenuation or preamplification is considered when the trigger level is analyzed. If defined, a reference level offset is also considered. The input signal must be between 500 MHz and 8 GHz. Is only available for triggered gated measurements (method RsFsw.sense.sweep.egate.auto.set() MAN) .

set(level: float) None[source]
# [SENSe]:SWEep:EGATe:LEVel:RFPower
driver.applications.k14Xnr5G.sense.sweep.egate.level.rfPower.set(level = 1.0)

Defines the gate level for which the gate is open. Note that any RF attenuation or preamplification is considered when the trigger level is analyzed. If defined, a reference level offset is also considered. The input signal must be between 500 MHz and 8 GHz. Is only available for triggered gated measurements (method RsFsw.sense.sweep.egate.auto.set() MAN) .

Parameters:

level – For details on available trigger levels and trigger bandwidths, refer to the specifications document. Unit: DBM