Source:Bb:Nr5G:Tcw#

SCPI Commands

[SOURce<HW>]:BB:NR5G:TCW:BEWPhi
[SOURce<HW>]:BB:NR5G:TCW:BEWThet
[SOURce<HW>]:BB:NR5G:TCW:BSCLass
[SOURce<HW>]:BB:NR5G:TCW:BSTYpe
[SOURce<HW>]:BB:NR5G:TCW:DCLDirection
[SOURce<HW>]:BB:NR5G:TCW:E50
[SOURce<HW>]:BB:NR5G:TCW:FR
[SOURce<HW>]:BB:NR5G:TCW:GENSignal
[SOURce<HW>]:BB:NR5G:TCW:INSTsetup
[SOURce<HW>]:BB:NR5G:TCW:MARKerconfig
[SOURce<HW>]:BB:NR5G:TCW:MEIS
[SOURce<HW>]:BB:NR5G:TCW:OPTStr
[SOURce<HW>]:BB:NR5G:TCW:RELease
[SOURce<HW>]:BB:NR5G:TCW:SPEC
[SOURce<HW>]:BB:NR5G:TCW:TC
[SOURce<HW>]:BB:NR5G:TCW:TRIGgerconfig

Cloning the Group

// Create a clone of the original group, that exists independently
var tcw2 = driver.Source.Bb.Nr5G.Tcw.Clone();

Direct SCPI Members

double Bewphi#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:BEWPhi
double value = driver.Source.Bb.Nr5G.Tcw.Bewphi;
driver.Source.Bb.Nr5G.Tcw.Bewphi = 1.0;

Sets the angle of the beamwidth for to the OTA REFSENS RoAoA in the φ-axis (BeWθ,REFSENS) , applicable for FR1 only.

bewphiRefSens: float


double Bewthet#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:BEWThet
double value = driver.Source.Bb.Nr5G.Tcw.Bewthet;
driver.Source.Bb.Nr5G.Tcw.Bewthet = 1.0;

Sets the angle of the beamwidth for to the OTA REFSENS RoAoA in the θ-axis (BeWθ,REFSENS) , applicable for FR1 only.

bewthetRefSens: float


BsClassEnum BsClass#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:BSCLass
BsClassEnum value = driver.Source.Bb.Nr5G.Tcw.BsClass;
driver.Source.Bb.Nr5G.Tcw.BsClass = BsClassEnum.LOC;

Sets the NR base station class.

bsClass: WIDE | MED | LOC


BsTypeEnum BsType#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:BSTYpe
BsTypeEnum value = driver.Source.Bb.Nr5G.Tcw.BsType;
driver.Source.Bb.Nr5G.Tcw.BsType = BsTypeEnum.BT1H;

Sets the base station type for the OTA settings as specified in TS 38.141-2 D.5.

bsType: BT1H | BT1O | BT2O

  • BT1: Sets the BS type 1-H (FR1, hybrid) for the OTA settings.

  • BT1O: Sets the BS type 1-O (FR1) for the OTA settings.

  • BT2O: Sets the BS type 2-O (FR2) for the OTA settings.


DeclaredDirEnum DclDirection#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:DCLDirection
DeclaredDirEnum value = driver.Source.Bb.Nr5G.Tcw.DclDirection;
driver.Source.Bb.Nr5G.Tcw.DclDirection = DeclaredDirEnum.MREFD;

Sets the reference for the OSDD.

declaredDir: OTHD | MREFD | OREFD

  • OTHD: Sets a value different than the minSENS and REFSENS as the reference for the OSDD.

  • MREFD: Sets the OTA minimum sensitivity (minSENS) value as the reference for the OSDD.

  • OREFD: Sets the OTA reference sensitivity (REFSENS) value as the reference for the OSDD.


double E50#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:E50
double value = driver.Source.Bb.Nr5G.Tcw.E50;
driver.Source.Bb.Nr5G.Tcw.E50 = 1.0;

Sets the EISREFSENS_50M level value applicable in the OTA REFSENS RoAoA as specified in TS 38.141-2 D.28. The EISREFSENS_50M value is the declared OTA reference sensitivity basis level for FR2 based on a reference measurement channel with 50MHz BS channel bandwidth.

eis50M: float


FreqRangeEnum Fr#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:FR
FreqRangeEnum value = driver.Source.Bb.Nr5G.Tcw.Fr;
driver.Source.Bb.Nr5G.Tcw.Fr = FreqRangeEnum.FR2GT37;

Sets the frequency range FR2 for the BS type 2-O. To reach the frequency range FR2, connect an external RF device to your instrument, e.g. an R&S SGS100A.

freqRange: FR2LT334 | FR2GT37

  • FR2LT334: Sets the FR2 range to 24.24 GHz f ≤ 33.4 GHz

  • FR2GT37: Sets the FR2 range to 37 GHz f ≤ 52.6 GHz


GenSigEnum GenSignal#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:GENSignal
GenSigEnum value = driver.Source.Bb.Nr5G.Tcw.GenSignal;
driver.Source.Bb.Nr5G.Tcw.GenSignal = GenSigEnum.ALL;

Selects the generated signal.


InstSetupEnum InstSetup#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:INSTsetup
InstSetupEnum value = driver.Source.Bb.Nr5G.Tcw.InstSetup;
driver.Source.Bb.Nr5G.Tcw.InstSetup = InstSetupEnum.U1PORT;

Selects the number of RF ports used for the test case. Prerequisites for this command

  • Select an OTA test case that supports different number of RF ports.


MarkConfEnum MarkerConfig#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:MARKerconfig
MarkConfEnum value = driver.Source.Bb.Nr5G.Tcw.MarkerConfig;
driver.Source.Bb.Nr5G.Tcw.MarkerConfig = MarkConfEnum.FRAM;

Selects the marker configuration. The marker can be used to synchronize the measuring equipment to the signal generator.

markerConfig: FRAM | UNCH

  • FRAM: The marker settings are customized for the selected test case. Radio Frame Start markers are output; the marker delays are set equal to zero.

  • UNCH: The current marker settings of the signal generator are retained unchanged.


double Meis#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:MEIS
double value = driver.Source.Bb.Nr5G.Tcw.Meis;
driver.Source.Bb.Nr5G.Tcw.Meis = 1.0;

Sets the lowest equivalent isotropic sensitivity value (EISminSENS) for the OSDD as specified in TS 38.141-2 D.27.

minimumEis: float


string OptStr#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:OPTStr
string value = driver.Source.Bb.Nr5G.Tcw.OptStr;

Queries missing options for the selected test case if there are any.

optionStr: string


ReleaseEnum Release#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:RELease
ReleaseEnum value = driver.Source.Bb.Nr5G.Tcw.Release;
driver.Source.Bb.Nr5G.Tcw.Release = ReleaseEnum.REL15;

Sets the 3GPP test specification used as a guideline for the test cases.

release: REL15 | REL16 | REL17


TestSpecEnum Spec#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:SPEC
TestSpecEnum value = driver.Source.Bb.Nr5G.Tcw.Spec;
driver.Source.Bb.Nr5G.Tcw.Spec = TestSpecEnum.TS38104;

Specifies the 3GPP test specification.

testSpec: TS38141_1 | TS38141_2 | TS38104


TestCaseEnum Tc#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:TC
TestCaseEnum value = driver.Source.Bb.Nr5G.Tcw.Tc;
driver.Source.Bb.Nr5G.Tcw.Tc = TestCaseEnum.TS381411_TC67;

Selects the test case.

testCase: The first part of the parameter indicates the standard document and the second part the chapter in which the test case is defined. For example, TS381411_TC72 defines the test case specified in TS 38.141-1 chapter 7.2.


TrigConfEnum TriggerConfig#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:TRIGgerconfig
TrigConfEnum value = driver.Source.Bb.Nr5G.Tcw.TriggerConfig;
driver.Source.Bb.Nr5G.Tcw.TriggerConfig = TrigConfEnum.AAUT;

Selects the trigger configuration. The trigger is used to synchronize the signal generator to the other equipment.

trigConfig: AAUT | UNCH

  • AAUT: The trigger settings are customized for the selected test case.The trigger setting Armed Auto with external trigger source is used; the trigger delay is set to zero.Thus, the base station frame timing is able to synchronize the signal generator by a periodic trigger.

  • UNCH: The current trigger settings of the signal generator are retained unchanged.