Source:Bb:Nr5G:Tcw#
SCPI Commands
- [SOURce<HW>]:BB:NR5G:TCW:BEWPhi
- [SOURce<HW>]:BB:NR5G:TCW:BEWThet
- [SOURce<HW>]:BB:NR5G:TCW:BSCLass
- [SOURce<HW>]:BB:NR5G:TCW:BSTYpe
- [SOURce<HW>]:BB:NR5G:TCW:DCLDirection
- [SOURce<HW>]:BB:NR5G:TCW:E50
- [SOURce<HW>]:BB:NR5G:TCW:FR
- [SOURce<HW>]:BB:NR5G:TCW:GENSignal
- [SOURce<HW>]:BB:NR5G:TCW:INSTsetup
- [SOURce<HW>]:BB:NR5G:TCW:MARKerconfig
- [SOURce<HW>]:BB:NR5G:TCW:MEIS
- [SOURce<HW>]:BB:NR5G:TCW:OPTStr
- [SOURce<HW>]:BB:NR5G:TCW:RELease
- [SOURce<HW>]:BB:NR5G:TCW:SPEC
- [SOURce<HW>]:BB:NR5G:TCW:TC
- [SOURce<HW>]:BB:NR5G:TCW:TRIGgerconfig
Cloning the Group
// Create a clone of the original group, that exists independently
var tcw2 = driver.Source.Bb.Nr5G.Tcw.Clone();
Direct SCPI Members
- double Bewphi#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:BEWPhi double value = driver.Source.Bb.Nr5G.Tcw.Bewphi; driver.Source.Bb.Nr5G.Tcw.Bewphi = 1.0;Sets the angle of the beamwidth for to the OTA REFSENS RoAoA in the φ-axis (BeWθ,REFSENS) , applicable for FR1 only.
bewphiRefSens: float
- double Bewthet#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:BEWThet double value = driver.Source.Bb.Nr5G.Tcw.Bewthet; driver.Source.Bb.Nr5G.Tcw.Bewthet = 1.0;Sets the angle of the beamwidth for to the OTA REFSENS RoAoA in the θ-axis (BeWθ,REFSENS) , applicable for FR1 only.
bewthetRefSens: float
- BsClassEnum BsClass#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:BSCLass BsClassEnum value = driver.Source.Bb.Nr5G.Tcw.BsClass; driver.Source.Bb.Nr5G.Tcw.BsClass = BsClassEnum.LOC;Sets the NR base station class.
bsClass: WIDE | MED | LOC
- BsTypeEnum BsType#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:BSTYpe BsTypeEnum value = driver.Source.Bb.Nr5G.Tcw.BsType; driver.Source.Bb.Nr5G.Tcw.BsType = BsTypeEnum.BT1H;Sets the base station type for the OTA settings as specified in TS 38.141-2 D.5.
bsType: BT1H | BT1O | BT2O
BT1: Sets the BS type 1-H (FR1, hybrid) for the OTA settings.
BT1O: Sets the BS type 1-O (FR1) for the OTA settings.
BT2O: Sets the BS type 2-O (FR2) for the OTA settings.
- DeclaredDirEnum DclDirection#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:DCLDirection DeclaredDirEnum value = driver.Source.Bb.Nr5G.Tcw.DclDirection; driver.Source.Bb.Nr5G.Tcw.DclDirection = DeclaredDirEnum.MREFD;Sets the reference for the OSDD.
declaredDir: OTHD | MREFD | OREFD
OTHD: Sets a value different than the minSENS and REFSENS as the reference for the OSDD.
MREFD: Sets the OTA minimum sensitivity (minSENS) value as the reference for the OSDD.
OREFD: Sets the OTA reference sensitivity (REFSENS) value as the reference for the OSDD.
- double E50#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:E50 double value = driver.Source.Bb.Nr5G.Tcw.E50; driver.Source.Bb.Nr5G.Tcw.E50 = 1.0;Sets the EISREFSENS_50M level value applicable in the OTA REFSENS RoAoA as specified in TS 38.141-2 D.28. The EISREFSENS_50M value is the declared OTA reference sensitivity basis level for FR2 based on a reference measurement channel with 50MHz BS channel bandwidth.
eis50M: float
- FreqRangeEnum Fr#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:FR FreqRangeEnum value = driver.Source.Bb.Nr5G.Tcw.Fr; driver.Source.Bb.Nr5G.Tcw.Fr = FreqRangeEnum.FR2GT37;Sets the frequency range FR2 for the BS type 2-O. To reach the frequency range FR2, connect an external RF device to your instrument, e.g. an R&S SGS100A.
freqRange: FR2LT334 | FR2GT37
FR2LT334: Sets the FR2 range to 24.24 GHz f ≤ 33.4 GHz
FR2GT37: Sets the FR2 range to 37 GHz f ≤ 52.6 GHz
- GenSigEnum GenSignal#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:GENSignal GenSigEnum value = driver.Source.Bb.Nr5G.Tcw.GenSignal; driver.Source.Bb.Nr5G.Tcw.GenSignal = GenSigEnum.ALL;Selects the generated signal.
- InstSetupEnum InstSetup#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:INSTsetup InstSetupEnum value = driver.Source.Bb.Nr5G.Tcw.InstSetup; driver.Source.Bb.Nr5G.Tcw.InstSetup = InstSetupEnum.U1PORT;Selects the number of RF ports used for the test case. Prerequisites for this command
Select an OTA test case that supports different number of RF ports.
- MarkConfEnum MarkerConfig#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:MARKerconfig MarkConfEnum value = driver.Source.Bb.Nr5G.Tcw.MarkerConfig; driver.Source.Bb.Nr5G.Tcw.MarkerConfig = MarkConfEnum.FRAM;Selects the marker configuration. The marker can be used to synchronize the measuring equipment to the signal generator.
markerConfig: FRAM | UNCH
FRAM: The marker settings are customized for the selected test case. Radio Frame Start markers are output; the marker delays are set equal to zero.
UNCH: The current marker settings of the signal generator are retained unchanged.
- double Meis#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:MEIS double value = driver.Source.Bb.Nr5G.Tcw.Meis; driver.Source.Bb.Nr5G.Tcw.Meis = 1.0;Sets the lowest equivalent isotropic sensitivity value (EISminSENS) for the OSDD as specified in TS 38.141-2 D.27.
minimumEis: float
- string OptStr#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:OPTStr string value = driver.Source.Bb.Nr5G.Tcw.OptStr;Queries missing options for the selected test case if there are any.
optionStr: string
- ReleaseEnum Release#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:RELease ReleaseEnum value = driver.Source.Bb.Nr5G.Tcw.Release; driver.Source.Bb.Nr5G.Tcw.Release = ReleaseEnum.REL15;Sets the 3GPP test specification used as a guideline for the test cases.
release: REL15 | REL16 | REL17
- TestSpecEnum Spec#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:SPEC TestSpecEnum value = driver.Source.Bb.Nr5G.Tcw.Spec; driver.Source.Bb.Nr5G.Tcw.Spec = TestSpecEnum.TS38104;Specifies the 3GPP test specification.
testSpec: TS38141_1 | TS38141_2 | TS38104
- TestCaseEnum Tc#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:TC TestCaseEnum value = driver.Source.Bb.Nr5G.Tcw.Tc; driver.Source.Bb.Nr5G.Tcw.Tc = TestCaseEnum.TS381411_TC67;Selects the test case.
testCase: The first part of the parameter indicates the standard document and the second part the chapter in which the test case is defined. For example, TS381411_TC72 defines the test case specified in TS 38.141-1 chapter 7.2.
- TrigConfEnum TriggerConfig#
// SCPI: [SOURce<HW>]:BB:NR5G:TCW:TRIGgerconfig TrigConfEnum value = driver.Source.Bb.Nr5G.Tcw.TriggerConfig; driver.Source.Bb.Nr5G.Tcw.TriggerConfig = TrigConfEnum.AAUT;Selects the trigger configuration. The trigger is used to synchronize the signal generator to the other equipment.
trigConfig: AAUT | UNCH
AAUT: The trigger settings are customized for the selected test case.The trigger setting Armed Auto with external trigger source is used; the trigger delay is set to zero.Thus, the base station frame timing is able to synchronize the signal generator by a periodic trigger.
UNCH: The current trigger settings of the signal generator are retained unchanged.
Subgroups