Generate#

SCPI Command :

CONFigure:DPD:FILE:GENerate
Commands in total: 2
Subgroups: 1
Direct child commands: 1
set ( ) → None
set_with_opc ( opc_timeout_ms: int = -1 ) → None
# CONFigure:DPD:FILE:GENerate
# set:
driver.applications.k18AmplifierEt.configure.dpd.file.generate.set()
# set_with_opc:
driver.applications.k18AmplifierEt.configure.dpd.file.generate.set_with_opc(opc_timeout_ms = 3000)

This command generates the waveform files containing predistortion information within the amplifier application. All in all, the command generates three waveform files: AM/AM only, AM/PM only and AM/AM plus AM/PM. It also transfers these waveform files to the connected signal generator. Prerequisites for this command

  • Turn on polynomial DPD (CONFigure:DDPD[:STATe]) .

set_with_opc() does the same as set(), but waits for the operation to complete before continuing further. Use the RsFsw.utilities.opc_timeout to set the timeout value.

Parameters:

opc_timeout_ms – Maximum time to wait in milliseconds, valid only for this call.

Cloning the Group

# Create a copy of the original group, that exists independently
generate_copy = driver.applications.k18AmplifierEt.configure.dpd.file.generate.clone()