Source:Frequency#

SCPI Commands

[SOURce<HW>]:FREQuency:CENTer
[SOURce<HW>]:FREQuency:FREQuency
[SOURce<HW>]:FREQuency:MANual
[SOURce<HW>]:FREQuency:MODE
[SOURce<HW>]:FREQuency:MULTiplier
[SOURce<HW>]:FREQuency:OFFSet
[SOURce<HW>]:FREQuency:SPAN
[SOURce<HW>]:FREQuency:STARt
[SOURce<HW>]:FREQuency:STOP

Cloning the Group

// Create a clone of the original group, that exists independently
var frequency2 = driver.Source.Frequency.Clone();

Direct SCPI Members

double Center#
// SCPI: [SOURce<HW>]:FREQuency:CENTer
double value = driver.Source.Frequency.Center;
driver.Source.Frequency.Center = 1.0;

Sets the center frequency of the sweep. The maximum value depends on the installed hardware options. For more information, refer to the specifications document.

center: float


double Frequency#
// SCPI: [SOURce<HW>]:FREQuency:FREQuency
double value = driver.Source.Frequency.Frequency;
driver.Source.Frequency.Frequency = 1.0;

No help available.


double Manual#
// SCPI: [SOURce<HW>]:FREQuency:MANual
double value = driver.Source.Frequency.Manual;
driver.Source.Frequency.Manual = 1.0;

Sets the frequency and triggers a sweep step manually if SWEep:MODE MAN.

manual: You can select any frequency within the setting range, where: STARt is set with method RsSmw.Source.Frequency.Start() STOP is set with method RsSmw.Source.Frequency.Stop() OFFSet is set with method RsSmw.Source.Frequency.Offset()


FreqModeEnum Mode#
// SCPI: [SOURce<HW>]:FREQuency:MODE
FreqModeEnum value = driver.Source.Frequency.Mode;
driver.Source.Frequency.Mode = FreqModeEnum.COMBined;

Sets the frequency mode for generating the RF output signal. The selected mode determines the parameters to be used for further frequency settings.

mode: CW | FIXed | SWEep | LIST

  • CW | FIXed: Sets the fixed frequency mode. CW and FIXed are synonyms.The instrument operates at a defined frequency, set with command [:SOURcehw]:FREQuency[:CW | FIXed].

  • SWEep: Sets sweep mode.The instrument processes frequency (and level) settings in defined sweep steps.Set the range and current frequency with the commands:[:SOURcehw]:FREQuency:STARt and [:SOURcehw]:FREQuency:STOP,[:SOURcehw]:FREQuency:CENTer,[:SOURcehw]:FREQuency:SPAN,[:SOURcehw]:FREQuency:MANual

  • LIST: Sets list mode.The instrument processes frequency and level settings by means of values loaded from a list.To configure list mode settings, use the commands of the “SOURce:LIST subsystem”.


double Multiplier#
// SCPI: [SOURce<HW>]:FREQuency:MULTiplier
double value = driver.Source.Frequency.Multiplier;
driver.Source.Frequency.Multiplier = 1.0;

Sets the multiplication factor NFREQ:MULT of a subsequent downstream instrument. The parameters offset fFREQ:OFFSer and multiplier NFREQ:MULT affect the frequency value set with the command method RsSmw.Source.Frequency.Cw.Value. The query method RsSmw.Source.Frequency.Cw.Value returns the value corresponding to the formula: fFREQ = fRFout * NFREQ:MULT + fFREQ:OFFSer See “Displayed RF frequency and level values with downstream instruments”.

multiplier: float


double Offset#
// SCPI: [SOURce<HW>]:FREQuency:OFFSet
double value = driver.Source.Frequency.Offset;
driver.Source.Frequency.Offset = 1.0;

Sets the frequency offset fFREQ:OFFSet of a downstream instrument. The parameters offset fFREQ:OFFSer and multiplier NFREQ:MULT affect the frequency value set with the command method RsSmw.Source.Frequency.Cw.Value. The query method RsSmw.Source.Frequency.Cw.Value returns the value corresponding to the formula: fFREQ = fRFout * NFREQ:MULT + fFREQ:OFFSer See “Displayed RF frequency and level values with downstream instruments”. Note: The offset also affects RF frequency sweep.

offset: float


double Span#
// SCPI: [SOURce<HW>]:FREQuency:SPAN
double value = driver.Source.Frequency.Span;
driver.Source.Frequency.Span = 1.0;

Sets the span of the frequency sweep range.

span: Full frequency range


double Start#
// SCPI: [SOURce<HW>]:FREQuency:STARt
double value = driver.Source.Frequency.Start;
driver.Source.Frequency.Start = 1.0;

Sets the start frequency for the RF sweep. The maximum value depends on the installed hardware options. For more information, refer to the specifications document.

start: float


double Stop#
// SCPI: [SOURce<HW>]:FREQuency:STOP
double value = driver.Source.Frequency.Stop;
driver.Source.Frequency.Stop = 1.0;

Sets the stop frequency range for the RF sweep. The maximum value depends on the installed hardware options. For more information, refer to the specifications document.

stop: float


Subgroups