Source:Frequency#
SCPI Commands
- [SOURce<HW>]:FREQuency:CENTer
- [SOURce<HW>]:FREQuency:FREQuency
- [SOURce<HW>]:FREQuency:MANual
- [SOURce<HW>]:FREQuency:MODE
- [SOURce<HW>]:FREQuency:MULTiplier
- [SOURce<HW>]:FREQuency:OFFSet
- [SOURce<HW>]:FREQuency:SPAN
- [SOURce<HW>]:FREQuency:STARt
- [SOURce<HW>]:FREQuency:STOP
Cloning the Group
// Create a clone of the original group, that exists independently
var frequency2 = driver.Source.Frequency.Clone();
Direct SCPI Members
- double Center#
// SCPI: [SOURce<HW>]:FREQuency:CENTer double value = driver.Source.Frequency.Center; driver.Source.Frequency.Center = 1.0;Sets the center frequency of the sweep. The maximum value depends on the installed hardware options. For more information, refer to the specifications document.
center: float
- double Frequency#
// SCPI: [SOURce<HW>]:FREQuency:FREQuency double value = driver.Source.Frequency.Frequency; driver.Source.Frequency.Frequency = 1.0;No help available.
- double Manual#
// SCPI: [SOURce<HW>]:FREQuency:MANual double value = driver.Source.Frequency.Manual; driver.Source.Frequency.Manual = 1.0;Sets the frequency and triggers a sweep step manually if SWEep:MODE MAN.
manual: You can select any frequency within the setting range, where: STARt is set with method RsSmw.Source.Frequency.Start() STOP is set with method RsSmw.Source.Frequency.Stop() OFFSet is set with method RsSmw.Source.Frequency.Offset()
- FreqModeEnum Mode#
// SCPI: [SOURce<HW>]:FREQuency:MODE FreqModeEnum value = driver.Source.Frequency.Mode; driver.Source.Frequency.Mode = FreqModeEnum.COMBined;Sets the frequency mode for generating the RF output signal. The selected mode determines the parameters to be used for further frequency settings.
mode: CW | FIXed | SWEep | LIST
CW | FIXed: Sets the fixed frequency mode. CW and FIXed are synonyms.The instrument operates at a defined frequency, set with command [:SOURcehw]:FREQuency[:CW | FIXed].
SWEep: Sets sweep mode.The instrument processes frequency (and level) settings in defined sweep steps.Set the range and current frequency with the commands:[:SOURcehw]:FREQuency:STARt and [:SOURcehw]:FREQuency:STOP,[:SOURcehw]:FREQuency:CENTer,[:SOURcehw]:FREQuency:SPAN,[:SOURcehw]:FREQuency:MANual
LIST: Sets list mode.The instrument processes frequency and level settings by means of values loaded from a list.To configure list mode settings, use the commands of the “SOURce:LIST subsystem”.
- double Multiplier#
// SCPI: [SOURce<HW>]:FREQuency:MULTiplier double value = driver.Source.Frequency.Multiplier; driver.Source.Frequency.Multiplier = 1.0;Sets the multiplication factor NFREQ:MULT of a subsequent downstream instrument. The parameters offset fFREQ:OFFSer and multiplier NFREQ:MULT affect the frequency value set with the command method RsSmw.Source.Frequency.Cw.Value. The query method RsSmw.Source.Frequency.Cw.Value returns the value corresponding to the formula: fFREQ = fRFout * NFREQ:MULT + fFREQ:OFFSer See “Displayed RF frequency and level values with downstream instruments”.
multiplier: float
- double Offset#
// SCPI: [SOURce<HW>]:FREQuency:OFFSet double value = driver.Source.Frequency.Offset; driver.Source.Frequency.Offset = 1.0;Sets the frequency offset fFREQ:OFFSet of a downstream instrument. The parameters offset fFREQ:OFFSer and multiplier NFREQ:MULT affect the frequency value set with the command method RsSmw.Source.Frequency.Cw.Value. The query method RsSmw.Source.Frequency.Cw.Value returns the value corresponding to the formula: fFREQ = fRFout * NFREQ:MULT + fFREQ:OFFSer See “Displayed RF frequency and level values with downstream instruments”. Note: The offset also affects RF frequency sweep.
offset: float
- double Span#
// SCPI: [SOURce<HW>]:FREQuency:SPAN double value = driver.Source.Frequency.Span; driver.Source.Frequency.Span = 1.0;Sets the span of the frequency sweep range.
span: Full frequency range
- double Start#
// SCPI: [SOURce<HW>]:FREQuency:STARt double value = driver.Source.Frequency.Start; driver.Source.Frequency.Start = 1.0;Sets the start frequency for the RF sweep. The maximum value depends on the installed hardware options. For more information, refer to the specifications document.
start: float
- double Stop#
// SCPI: [SOURce<HW>]:FREQuency:STOP double value = driver.Source.Frequency.Stop; driver.Source.Frequency.Stop = 1.0;Sets the stop frequency range for the RF sweep. The maximum value depends on the installed hardware options. For more information, refer to the specifications document.
stop: float