Hp5Bits
SCPI Command :
[SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:PDSCh:HP5Bits
- class Hp5BitsCls[source]
Hp5Bits commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default) bool [source]
# SCPI: [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:PDSCh:HP5Bits value: bool = driver.source.bb.nr5G.ubwp.user.cell.downlink.bwp.pdsch.hp5Bits.get(userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default)
Selects the size of the ‘HARQ Process Number’ DCI field in DCI format 1_1.
- param userNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)
- param cellNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- param bwPartNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)
- return
harq_proc_5_bits: No help available
- set(harq_proc_5_bits: bool, userNull=UserNull.Default, cellNull=CellNull.Default, bwPartNull=BwPartNull.Default) None [source]
# SCPI: [SOURce<HW>]:BB:NR5G:UBWP:USER<US(CH0)>:CELL<CC(ST0)>:DL:BWP<BWP(DIR0)>:PDSCh:HP5Bits driver.source.bb.nr5G.ubwp.user.cell.downlink.bwp.pdsch.hp5Bits.set(harq_proc_5_bits = False, userNull = repcap.UserNull.Default, cellNull = repcap.CellNull.Default, bwPartNull = repcap.BwPartNull.Default)
Selects the size of the ‘HARQ Process Number’ DCI field in DCI format 1_1.
- param harq_proc_5_bits
OFF | 0 4 bits ON | 1 5 bits
- param userNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)
- param cellNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- param bwPartNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Bwp’)