Center
SCPI Command :
[SENSe]:POWer:ACHannel:SBLock<sb>:FREQuency:CENTer
- class CenterCls[source]
Center commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(subBlock=SubBlock.Default) float [source]
# SCPI: [SENSe]:POWer:ACHannel:SBLock<sb>:FREQuency:CENTer value: float = driver.applications.k10Xlte.sense.power.achannel.sblock.frequency.center.get(subBlock = repcap.SubBlock.Default)
Defines the center of the specified MSR sub block. Note that the position of the sub block also affects the position of the adjacent gap (CACLR) channels. Is for MSR signals only (see method RsFsw.Calculate.Marker.Function.Power.preset) . For details on MSR signals see ‘Measurement on multi-standard radio (MSR) signals’.
- param subBlock
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Sblock’)
- return
frequency: absolute frequency in Hz Unit: Hz
- set(frequency: float, subBlock=SubBlock.Default) None [source]
# SCPI: [SENSe]:POWer:ACHannel:SBLock<sb>:FREQuency:CENTer driver.applications.k10Xlte.sense.power.achannel.sblock.frequency.center.set(frequency = 1.0, subBlock = repcap.SubBlock.Default)
Defines the center of the specified MSR sub block. Note that the position of the sub block also affects the position of the adjacent gap (CACLR) channels. Is for MSR signals only (see method RsFsw.Calculate.Marker.Function.Power.preset) . For details on MSR signals see ‘Measurement on multi-standard radio (MSR) signals’.
- param frequency
absolute frequency in Hz Unit: Hz
- param subBlock
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Sblock’)