UpInterval

SCPI Command :

[SOURce<HW>]:REGenerator:OBJect<CH>:RCS:UPINterval
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(objectIx=ObjectIx.Default) float[source]
# [SOURce<HW>]:REGenerator:OBJect<CH>:RCS:UPINterval
value: float = driver.source.regenerator.object.rcs.upInterval.get(objectIx = repcap.ObjectIx.Default)

Queries how often a new swerling random value is created.

Parameters:

objectIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Object’)

Returns:

rcs_update_interv: float Range: 3.74742E-5 to 3600