Real
SCPI Command :
[SOURce<HW>]:BB:V5G:DL:USER<CH>:APM:[LAYer<USER>]:AP<DIR0>:ROW<ST0>:REAL
- class RealCls[source]
Real commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(userIx=UserIx.Default, layerNull=LayerNull.Default, antennaPortNull=AntennaPortNull.Default, row=Row.Default) float [source]
# SCPI: [SOURce<HW>]:BB:V5G:DL:USER<CH>:APM:[LAYer<USER>]:AP<DIR0>:ROW<ST0>:REAL value: float = driver.source.bb.v5G.downlink.user.apm.layer.ap.row.real.get(userIx = repcap.UserIx.Default, layerNull = repcap.LayerNull.Default, antennaPortNull = repcap.AntennaPortNull.Default, row = repcap.Row.Default)
- Defines the mapping of the antenna ports to the physical antennas:
INTRO_CMD_HELP: Selects the clock source:
Per user (1 to 4) ,
Per layer (1 to 2) ,
Per antenna port (8 to 15 and 60, 61, 107, 109) , and
Per row selecting baseband (0 to 7) .
The command specifies real / magnitude part.
- param userIx
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘User’)
- param layerNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Layer’)
- param antennaPortNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Ap’)
- param row
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Row’)
- return
ant_port_map_data: float The REAL (magnitude) and IMAGinary (phase) values are interdependent. Their value ranges change depending on each other and so that the resulting complex value is as follows: |REAL+j*IMAGinary| <= 1 Otherwise, the values are normalized to magnitude = 1. Range: -1 to 360
- set(ant_port_map_data: float, userIx=UserIx.Default, layerNull=LayerNull.Default, antennaPortNull=AntennaPortNull.Default, row=Row.Default) None [source]
# SCPI: [SOURce<HW>]:BB:V5G:DL:USER<CH>:APM:[LAYer<USER>]:AP<DIR0>:ROW<ST0>:REAL driver.source.bb.v5G.downlink.user.apm.layer.ap.row.real.set(ant_port_map_data = 1.0, userIx = repcap.UserIx.Default, layerNull = repcap.LayerNull.Default, antennaPortNull = repcap.AntennaPortNull.Default, row = repcap.Row.Default)
- Defines the mapping of the antenna ports to the physical antennas:
INTRO_CMD_HELP: Selects the clock source:
Per user (1 to 4) ,
Per layer (1 to 2) ,
Per antenna port (8 to 15 and 60, 61, 107, 109) , and
Per row selecting baseband (0 to 7) .
The command specifies real / magnitude part.
- param ant_port_map_data
float The REAL (magnitude) and IMAGinary (phase) values are interdependent. Their value ranges change depending on each other and so that the resulting complex value is as follows: |REAL+j*IMAGinary| <= 1 Otherwise, the values are normalized to magnitude = 1. Range: -1 to 360
- param userIx
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘User’)
- param layerNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Layer’)
- param antennaPortNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Ap’)
- param row
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Row’)