Trigger
SCPI Commands :
[SOURce<HW>]:BB:V5G:TRIGger:RMODe
[SOURce<HW>]:BB:V5G:TRIGger:SLENgth
[SOURce<HW>]:BB:V5G:TRIGger:SLUNit
[SOURce<HW>]:BB:V5G:TRIGger:SOURce
[SOURce<HW>]:BB:V5G:[TRIGger]:SEQuence
- class TriggerCls[source]
Trigger commands group definition. 30 total commands, 7 Subgroups, 5 group commands
- get_rmode() RsSmw.enums.TrigRunMode [source]
# SCPI: [SOURce<HW>]:BB:V5G:TRIGger:RMODe value: enums.TrigRunMode = driver.source.bb.v5G.trigger.get_rmode()
Queries the signal generation status.
- return
trig_run_mode: STOP| RUN
- get_sequence() RsSmw.enums.DmTrigMode [source]
# SCPI: [SOURce<HW>]:BB:V5G:[TRIGger]:SEQuence value: enums.DmTrigMode = driver.source.bb.v5G.trigger.get_sequence() INTRO_CMD_HELP: Selects the trigger mode: - AUTO = auto - RETRigger = retrigger - AAUTo = armed auto - ARETrigger = armed retrigger - SINGle = single :return: trig_mode: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
- get_sl_unit() RsSmw.enums.Unit [source]
# SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SLUNit value: enums.Unit = driver.source.bb.v5G.trigger.get_sl_unit()
Defines the unit for the entry of the signal sequence length, generated after the trigger event.
- return
seq_len_unit: SEQuence| FRAMe| SUBFrame| SLOT| SAMPle SEQuence Single sequence. FRAMe Single frame SUBFrame Single subframe. SLOT Single slot SAMPle Selected number of samples.
- get_slength() int [source]
# SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SLENgth value: int = driver.source.bb.v5G.trigger.get_slength()
Defines the length of the signal sequence that is output in the SINGle trigger mode.
- return
trig_seq_len: integer Range: 1 to 4294967295
- get_source() RsSmw.enums.TriggerSourceC [source]
# SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SOURce value: enums.TriggerSourceC = driver.source.bb.v5G.trigger.get_source() INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are: - Internal triggering by a command (INTernal) - External trigger signal via one of the local or global connectors Table Header: - EGT1|EGT2: External global trigger - EGC1|EGC2: External global clock - ELTRigger: External local trigger - ELCLock: External local clock - Internal triggering by a signal from the other basebands (INTA|INTB) - OBASeband|BEXTernal|EXTernal: Setting only Provided only for backward
compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
- return
trig_sour: INTB| INTernal| OBASeband| EGT1| EGT2| EGC1| EGC2| ELTRigger| INTA| ELCLock| BEXTernal| EXTernal
- set_sequence(trig_mode: RsSmw.enums.DmTrigMode) None [source]
# SCPI: [SOURce<HW>]:BB:V5G:[TRIGger]:SEQuence driver.source.bb.v5G.trigger.set_sequence(trig_mode = enums.DmTrigMode.AAUTo) INTRO_CMD_HELP: Selects the trigger mode: - AUTO = auto - RETRigger = retrigger - AAUTo = armed auto - ARETrigger = armed retrigger - SINGle = single :param trig_mode: AUTO| RETRigger| AAUTo| ARETrigger| SINGle
- set_sl_unit(seq_len_unit: RsSmw.enums.Unit) None [source]
# SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SLUNit driver.source.bb.v5G.trigger.set_sl_unit(seq_len_unit = enums.Unit.FRAMe)
Defines the unit for the entry of the signal sequence length, generated after the trigger event.
- param seq_len_unit
SEQuence| FRAMe| SUBFrame| SLOT| SAMPle SEQuence Single sequence. FRAMe Single frame SUBFrame Single subframe. SLOT Single slot SAMPle Selected number of samples.
- set_slength(trig_seq_len: int) None [source]
# SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SLENgth driver.source.bb.v5G.trigger.set_slength(trig_seq_len = 1)
Defines the length of the signal sequence that is output in the SINGle trigger mode.
- param trig_seq_len
integer Range: 1 to 4294967295
- set_source(trig_sour: RsSmw.enums.TriggerSourceC) None [source]
# SCPI: [SOURce<HW>]:BB:V5G:TRIGger:SOURce driver.source.bb.v5G.trigger.set_source(trig_sour = enums.TriggerSourceC.BBSY) INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are: - Internal triggering by a command (INTernal) - External trigger signal via one of the local or global connectors Table Header: - EGT1|EGT2: External global trigger - EGC1|EGC2: External global clock - ELTRigger: External local trigger - ELCLock: External local clock - Internal triggering by a signal from the other basebands (INTA|INTB) - OBASeband|BEXTernal|EXTernal: Setting only Provided only for backward
compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
- param trig_sour
INTB| INTernal| OBASeband| EGT1| EGT2| EGC1| EGC2| ELTRigger| INTA| ELCLock| BEXTernal| EXTernal
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.source.bb.v5G.trigger.clone()
Subgroups