Distance

SCPI Command :

[SOURce<HW>]:BB:TDSCdma:UP:CELL<ST>:SLOT<CH0>:PRAC:PTS:DISTance
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(cell=Cell.Default, slotNull=SlotNull.Default) int[source]
# [SOURce<HW>]:BB:TDSCdma:UP:CELL<ST>:SLOT<CH0>:PRAC:PTS:DISTance
value: int = driver.source.bb.tdscdma.up.cell.slot.prac.pts.distance.get(cell = repcap.Cell.Default, slotNull = repcap.SlotNull.Default)

Sets the value to vary the timing between UpPTS and RACH.

Parameters:
  • cell – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)

  • slotNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Slot’)

Returns:

distance: integer Range: 1 to 4

set(distance: int, cell=Cell.Default, slotNull=SlotNull.Default) None[source]
# [SOURce<HW>]:BB:TDSCdma:UP:CELL<ST>:SLOT<CH0>:PRAC:PTS:DISTance
driver.source.bb.tdscdma.up.cell.slot.prac.pts.distance.set(distance = 1, cell = repcap.Cell.Default, slotNull = repcap.SlotNull.Default)

Sets the value to vary the timing between UpPTS and RACH.

Parameters:
  • distance – integer Range: 1 to 4

  • cell – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)

  • slotNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Slot’)