SCPI Command :
[SOURce<HW>]:BB:TDSCdma:UP:CELL<ST>:ENH:DCH:DCCH:DATA
- Commands in total: 3Subgroups: 2Direct child commands: 1
- get(cell=Cell.Default) DataSourceA[source]
# [SOURce<HW>]:BB:TDSCdma:UP:CELL<ST>:ENH:DCH:DCCH:DATA value: enums.DataSourceA = driver.source.bb.tdscdma.up.cell.enh.dch.dcch.data.get(cell = repcap.Cell.Default)
The command selects the data source for the specified channel. For the traffic channels, this value is specific for the selected radio configuration.
- Parameters:
cell – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)
- Returns:
data: PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23 | DLISt | ZERO | ONE | PATTern PNxx PRBS data as per CCITT with period lengths between 29-1 and 223-1 is generated internally. DLISt Internal data from a programmable data list is used. The data list can be generated by the Data Editor or generated externally. Data lists are selected in the ‘Select Data List’ field. The data list is selected with the command BB:TDSC:DOWN:CELL1:ENH:BCH:DTCH:DATA:DSEL data list name. ZERO | ONE Internal 0 and 1 data is used. PATTern A user-definable bit pattern with a maximum length of 64 bits is generated internally. The bit pattern is defined in the ‘Pattern entry field’. The bit pattern is selected with the command BB:TDSC:DOWN:CELL1:ENH:BCH:DTCH:DATA:PATT bit pattern.
- set(data: DataSourceA, cell=Cell.Default) None[source]
# [SOURce<HW>]:BB:TDSCdma:UP:CELL<ST>:ENH:DCH:DCCH:DATA driver.source.bb.tdscdma.up.cell.enh.dch.dcch.data.set(data = enums.DataSourceA.DLISt, cell = repcap.Cell.Default)
The command selects the data source for the specified channel. For the traffic channels, this value is specific for the selected radio configuration.
- Parameters:
data – PN9 | PN11 | PN15 | PN16 | PN20 | PN21 | PN23 | DLISt | ZERO | ONE | PATTern PNxx PRBS data as per CCITT with period lengths between 29-1 and 223-1 is generated internally. DLISt Internal data from a programmable data list is used. The data list can be generated by the Data Editor or generated externally. Data lists are selected in the ‘Select Data List’ field. The data list is selected with the command BB:TDSC:DOWN:CELL1:ENH:BCH:DTCH:DATA:DSEL data list name. ZERO | ONE Internal 0 and 1 data is used. PATTern A user-definable bit pattern with a maximum length of 64 bits is generated internally. The bit pattern is defined in the ‘Pattern entry field’. The bit pattern is selected with the command BB:TDSC:DOWN:CELL1:ENH:BCH:DTCH:DATA:PATT bit pattern.
cell – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Cell’)
Cloning the Group
# Create a copy of the original group, that exists independently
data_copy = driver.source.bb.tdscdma.up.cell.enh.dch.dcch.data.clone()