Read

SCPI Command :

[SOURce<HW>]:BB:C2K:MSTation<ST>:TPC:READ
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(mobileStation=MobileStation.Default) TpcReadMode[source]
# [SOURce<HW>]:BB:C2K:MSTation<ST>:TPC:READ
value: enums.TpcReadMode = driver.source.bb.c2K.mstation.tpc.read.get(mobileStation = repcap.MobileStation.Default)

The command sets the read out mode for the bit pattern of the power control bits. The bit pattern is defined with the commands BB:C2K:MST<n>:TPC….

Parameters:

mobileStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)

Returns:

read: CONTinuous | S0A | S1A | S01A | S10A CONTinuous The bit pattern is used cyclically. S0A The bit pattern is used once, then the power control bit sequence continues with 0 bits. S1A The bit pattern is used once, then the power control bit sequence continues with 1 bit. S01A The bit pattern is used once and then the power control bit sequence is continued with 0 bits and 1 bit alternately. S10A The bit pattern is used once and then the power control bit sequence is continued with 1 bit and 0 bits alternately.

set(read: TpcReadMode, mobileStation=MobileStation.Default) None[source]
# [SOURce<HW>]:BB:C2K:MSTation<ST>:TPC:READ
driver.source.bb.c2K.mstation.tpc.read.set(read = enums.TpcReadMode.CONTinuous, mobileStation = repcap.MobileStation.Default)

The command sets the read out mode for the bit pattern of the power control bits. The bit pattern is defined with the commands BB:C2K:MST<n>:TPC….

Parameters:
  • read – CONTinuous | S0A | S1A | S01A | S10A CONTinuous The bit pattern is used cyclically. S0A The bit pattern is used once, then the power control bit sequence continues with 0 bits. S1A The bit pattern is used once, then the power control bit sequence continues with 1 bit. S01A The bit pattern is used once and then the power control bit sequence is continued with 0 bits and 1 bit alternately. S10A The bit pattern is used once and then the power control bit sequence is continued with 1 bit and 0 bits alternately.

  • mobileStation – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Mstation’)