Source code for RsSmw.Implementations.Source.Bb.C2K.Mstation.Tpc.Read

from .......Internal.Core import Core
from .......Internal.CommandsGroup import CommandsGroup
from .......Internal import Conversions
from ....... import enums
from ....... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class ReadCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("read", core, parent)

[docs] def set(self, read: enums.TpcReadMode, mobileStation=repcap.MobileStation.Default) -> None: """ ``[SOURce<HW>]:BB:C2K:MSTation<ST>:TPC:READ`` \n Snippet: ``driver.source.bb.c2K.mstation.tpc.read.set(read = enums.TpcReadMode.CONTinuous, mobileStation = repcap.MobileStation.Default)`` \n The command sets the read out mode for the bit pattern of the power control bits. The bit pattern is defined with the commands BB:C2K:MST<n>:TPC.... :param read: CONTinuous | S0A | S1A | S01A | S10A CONTinuous The bit pattern is used cyclically. S0A The bit pattern is used once, then the power control bit sequence continues with 0 bits. S1A The bit pattern is used once, then the power control bit sequence continues with 1 bit. S01A The bit pattern is used once and then the power control bit sequence is continued with 0 bits and 1 bit alternately. S10A The bit pattern is used once and then the power control bit sequence is continued with 1 bit and 0 bits alternately. :param mobileStation: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Mstation') """ param = Conversions.enum_scalar_to_str(read, enums.TpcReadMode) mobileStation_cmd_val = self._cmd_group.get_repcap_cmd_value(mobileStation, repcap.MobileStation) self._core.io.write(f'SOURce<HwInstance>:BB:C2K:MSTation{mobileStation_cmd_val}:TPC:READ {param}')
# noinspection PyTypeChecker
[docs] def get(self, mobileStation=repcap.MobileStation.Default) -> enums.TpcReadMode: """ ``[SOURce<HW>]:BB:C2K:MSTation<ST>:TPC:READ`` \n Snippet: ``value: enums.TpcReadMode = driver.source.bb.c2K.mstation.tpc.read.get(mobileStation = repcap.MobileStation.Default)`` \n The command sets the read out mode for the bit pattern of the power control bits. The bit pattern is defined with the commands BB:C2K:MST<n>:TPC.... :param mobileStation: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Mstation') :return: read: CONTinuous | S0A | S1A | S01A | S10A CONTinuous The bit pattern is used cyclically. S0A The bit pattern is used once, then the power control bit sequence continues with 0 bits. S1A The bit pattern is used once, then the power control bit sequence continues with 1 bit. S01A The bit pattern is used once and then the power control bit sequence is continued with 0 bits and 1 bit alternately. S10A The bit pattern is used once and then the power control bit sequence is continued with 1 bit and 0 bits alternately. """ mobileStation_cmd_val = self._cmd_group.get_repcap_cmd_value(mobileStation, repcap.MobileStation) response = self._core.io.query_str(f'SOURce<HwInstance>:BB:C2K:MSTation{mobileStation_cmd_val}:TPC:READ?') return Conversions.str_to_scalar_enum(response, enums.TpcReadMode)