Signal
SCPI Command :
OUTPut<HW>:USER<CH>:SIGNal
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(userIx=UserIx.Default) OutpConnGlbSignal[source]
# OUTPut<HW>:USER<CH>:SIGNal value: enums.OutpConnGlbSignal = driver.output.user.signal.get(userIx = repcap.UserIx.Default)
Sets the control signal that is output at the selected connector. To define the connector direction, use the command method
RsSmw.output.user.direction.set().- Parameters:
userIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘User’)
- Returns:
signal: MARKA1 | MARKA2 | MARKA3 | MARKB1 | MARKB2 | MARKB3 | MARKC1 | MARKC2 | MARKC3 | MARKD1 | MARKD2 | MARKD3 | SVALA | SVALB | OPULSA | OPULSB | SYNCA | VIDEOA | VIDEOB | SYNCB | NONE | RTRIGA | RTRIGB | SVALANegated | SVALBNegated | LOW | HIGH | MTRigger | SYNCOUT | BERRESTOUT | BERDATENOUT | BERCLKOUT | BERDATOUT MARKA | B|C | D1 | 2|3 = Baseband BB Marker 1/2/3 (available marker signals depend on the system configuration, see Table ‘Mapping control signals to the USER x connectors’) SVALA | SVALB = Signal Valid A/B, available for USER4 | 5|6 SVALANegated | SVALBNegated = Signal Valid A/B (negative) , available for USER4 | 5|6 OPULSA | OPULSB = Pulse Out A/B, available for USER4 | 5|6 SYNCA | SYNCB = Pulse Sync A/B, available for USER4 | 5|6 VIDEOA | VIDEOB = Pulse Video A/B, available for USER4 | 5|6 MTRigger = Manual Trigger, available for USER6 RTRIGA | RTRIGB = REG trigger A/B, available for USER4 | 5 BERRESTOUT | BERDATENOUT | BERCLKOUT | BERDATOUT = BERT TestGen Data, Clock, Data Enable and Restart SYNCOUT = Baseband Sync Out LOW | HIGH = Always 0/1 NONE = none
- set(signal: OutpConnGlbSignal, userIx=UserIx.Default) None[source]
# OUTPut<HW>:USER<CH>:SIGNal driver.output.user.signal.set(signal = enums.OutpConnGlbSignal.BERCLKOUT, userIx = repcap.UserIx.Default)
Sets the control signal that is output at the selected connector. To define the connector direction, use the command method
RsSmw.output.user.direction.set().- Parameters:
signal – MARKA1 | MARKA2 | MARKA3 | MARKB1 | MARKB2 | MARKB3 | MARKC1 | MARKC2 | MARKC3 | MARKD1 | MARKD2 | MARKD3 | SVALA | SVALB | OPULSA | OPULSB | SYNCA | VIDEOA | VIDEOB | SYNCB | NONE | RTRIGA | RTRIGB | SVALANegated | SVALBNegated | LOW | HIGH | MTRigger | SYNCOUT | BERRESTOUT | BERDATENOUT | BERCLKOUT | BERDATOUT MARKA | B|C | D1 | 2|3 = Baseband BB Marker 1/2/3 (available marker signals depend on the system configuration, see Table ‘Mapping control signals to the USER x connectors’) SVALA | SVALB = Signal Valid A/B, available for USER4 | 5|6 SVALANegated | SVALBNegated = Signal Valid A/B (negative) , available for USER4 | 5|6 OPULSA | OPULSB = Pulse Out A/B, available for USER4 | 5|6 SYNCA | SYNCB = Pulse Sync A/B, available for USER4 | 5|6 VIDEOA | VIDEOB = Pulse Video A/B, available for USER4 | 5|6 MTRigger = Manual Trigger, available for USER6 RTRIGA | RTRIGB = REG trigger A/B, available for USER4 | 5 BERRESTOUT | BERDATENOUT | BERCLKOUT | BERDATOUT = BERT TestGen Data, Clock, Data Enable and Restart SYNCOUT = Baseband Sync Out LOW | HIGH = Always 0/1 NONE = none
userIx – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘User’)