Signal
SCPI Command :
OUTPut<HW>:TM<CH>:SIGNal
- class SignalCls[source]
Signal commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(tmConnector=TmConnector.Default) OutpConnBbSignal [source]
# SCPI: OUTPut<HW>:TM<CH>:SIGNal value: enums.OutpConnBbSignal = driver.output.tm.signal.get(tmConnector = repcap.TmConnector.Default)
Determines the control signal that is output at the selected connector. To define the connector direction, use the command method RsSmw.Output.Tm.Direction.set.
- param tmConnector:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Tm’)
- return:
signal: MARKA1| MARKA2| MARKA3| SCLA| LATTA| BGATA| HOPA| CWMODA| TRIGA| MARKB1| MARKB2| MARKB3| SCLB| LATTB| BGATB| HOPB| CWMODB| TRIGB| MARKC1| MARKC2| MARKC3| SCLC| LATTC| BGATC| HOPC| CWMODC| TRIGC| MARKD1| MARKD2| MARKD3| SCLD| LATTD| BGATD| HOPD| CWMODD| TRIGD MARKA1|MARKC1|MARKA2|MARKC2|(MARKA3|MARKC3) = Baseband A/C Marker 1/2/(3) SCLA|SCLB|SCLC|SCLD = Symbol Clock A/B/C/D Option:R&S SMW-B10 LATTA|LATTB|LATTC|LATTD = Lev Att A/B/C/D BGATA|BGATB|BGATC|BGATD = Burst Gate A/B/C/D HOPA|HOPB|HOPC|HOPD = HOP A/B/C/D CWMODA|CWMODB|CWMODC|CWMODD = CW/Mod A/B/C/D TRIGA|TRIGB|TRIGC|TRIGD = Triggered A The character A/B/C/D in the parameter value indicates the baseband the signal is related to.
- set(signal: OutpConnBbSignal, tmConnector=TmConnector.Default) None [source]
# SCPI: OUTPut<HW>:TM<CH>:SIGNal driver.output.tm.signal.set(signal = enums.OutpConnBbSignal.BGATA, tmConnector = repcap.TmConnector.Default)
Determines the control signal that is output at the selected connector. To define the connector direction, use the command method RsSmw.Output.Tm.Direction.set.
- param signal:
MARKA1| MARKA2| MARKA3| SCLA| LATTA| BGATA| HOPA| CWMODA| TRIGA| MARKB1| MARKB2| MARKB3| SCLB| LATTB| BGATB| HOPB| CWMODB| TRIGB| MARKC1| MARKC2| MARKC3| SCLC| LATTC| BGATC| HOPC| CWMODC| TRIGC| MARKD1| MARKD2| MARKD3| SCLD| LATTD| BGATD| HOPD| CWMODD| TRIGD MARKA1|MARKC1|MARKA2|MARKC2|(MARKA3|MARKC3) = Baseband A/C Marker 1/2/(3) SCLA|SCLB|SCLC|SCLD = Symbol Clock A/B/C/D Option:R&S SMW-B10 LATTA|LATTB|LATTC|LATTD = Lev Att A/B/C/D BGATA|BGATB|BGATC|BGATD = Burst Gate A/B/C/D HOPA|HOPB|HOPC|HOPD = HOP A/B/C/D CWMODA|CWMODB|CWMODC|CWMODD = CW/Mod A/B/C/D TRIGA|TRIGB|TRIGC|TRIGD = Triggered A The character A/B/C/D in the parameter value indicates the baseband the signal is related to.
- param tmConnector:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Tm’)