Source code for RsSmw.Implementations.Output.Tm.Signal

from ....Internal.Core import Core
from ....Internal.CommandsGroup import CommandsGroup
from ....Internal import Conversions
from .... import enums
from .... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class SignalCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("signal", core, parent)

[docs] def set(self, signal: enums.OutpConnBbSignal, tmConnector=repcap.TmConnector.Default) -> None: """ ``OUTPut<HW>:TM<CH>:SIGNal`` \n Snippet: ``driver.output.tm.signal.set(signal = enums.OutpConnBbSignal.BGATA, tmConnector = repcap.TmConnector.Default)`` \n Determines the control signal that is output at the selected connector. To define the connector direction, use the command method ``RsSmw.output.tm.direction.set()`` . :param signal: MARKA1 | MARKA2 | MARKA3 | SCLA | LATTA | BGATA | HOPA | CWMODA | TRIGA | MARKB1 | MARKB2 | MARKB3 | SCLB | LATTB | BGATB | HOPB | CWMODB | TRIGB | MARKC1 | MARKC2 | MARKC3 | SCLC | LATTC | BGATC | HOPC | CWMODC | TRIGC | MARKD1 | MARKD2 | MARKD3 | SCLD | LATTD | BGATD | HOPD | CWMODD | TRIGD MARKA1 | MARKC1 | MARKA2 | MARKC2|(MARKA3 | MARKC3) = Baseband A/C Marker 1/2/(3) SCLA | SCLB | SCLC | SCLD = Symbol Clock A/B/C/D Option:R&S SMW-B10 LATTA | LATTB | LATTC | LATTD = Lev Att A/B/C/D BGATA | BGATB | BGATC | BGATD = Burst Gate A/B/C/D HOPA | HOPB | HOPC | HOPD = HOP A/B/C/D CWMODA | CWMODB | CWMODC | CWMODD = CW/Mod A/B/C/D TRIGA | TRIGB | TRIGC | TRIGD = Triggered A The character A/B/C/D in the parameter value indicates the baseband the signal is related to. :param tmConnector: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Tm') """ param = Conversions.enum_scalar_to_str(signal, enums.OutpConnBbSignal) tmConnector_cmd_val = self._cmd_group.get_repcap_cmd_value(tmConnector, repcap.TmConnector) self._core.io.write(f'OUTPut<HwInstance>:TM{tmConnector_cmd_val}:SIGNal {param}')
# noinspection PyTypeChecker
[docs] def get(self, tmConnector=repcap.TmConnector.Default) -> enums.OutpConnBbSignal: """ ``OUTPut<HW>:TM<CH>:SIGNal`` \n Snippet: ``value: enums.OutpConnBbSignal = driver.output.tm.signal.get(tmConnector = repcap.TmConnector.Default)`` \n Determines the control signal that is output at the selected connector. To define the connector direction, use the command method ``RsSmw.output.tm.direction.set()`` . :param tmConnector: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Tm') :return: signal: MARKA1 | MARKA2 | MARKA3 | SCLA | LATTA | BGATA | HOPA | CWMODA | TRIGA | MARKB1 | MARKB2 | MARKB3 | SCLB | LATTB | BGATB | HOPB | CWMODB | TRIGB | MARKC1 | MARKC2 | MARKC3 | SCLC | LATTC | BGATC | HOPC | CWMODC | TRIGC | MARKD1 | MARKD2 | MARKD3 | SCLD | LATTD | BGATD | HOPD | CWMODD | TRIGD MARKA1 | MARKC1 | MARKA2 | MARKC2|(MARKA3 | MARKC3) = Baseband A/C Marker 1/2/(3) SCLA | SCLB | SCLC | SCLD = Symbol Clock A/B/C/D Option:R&S SMW-B10 LATTA | LATTB | LATTC | LATTD = Lev Att A/B/C/D BGATA | BGATB | BGATC | BGATD = Burst Gate A/B/C/D HOPA | HOPB | HOPC | HOPD = HOP A/B/C/D CWMODA | CWMODB | CWMODC | CWMODD = CW/Mod A/B/C/D TRIGA | TRIGB | TRIGC | TRIGD = Triggered A The character A/B/C/D in the parameter value indicates the baseband the signal is related to. """ tmConnector_cmd_val = self._cmd_group.get_repcap_cmd_value(tmConnector, repcap.TmConnector) response = self._core.io.query_str(f'OUTPut<HwInstance>:TM{tmConnector_cmd_val}:SIGNal?') return Conversions.str_to_scalar_enum(response, enums.OutpConnBbSignal)