Source:Bb:Wlad:Trigger#
SCPI Commands
- [SOURce<HW>]:BB:WLAD:TRIGger:RMODe
- [SOURce<HW>]:BB:WLAD:TRIGger:SLENgth
- [SOURce<HW>]:BB:WLAD:TRIGger:SLUNit
- [SOURce<HW>]:BB:WLAD:TRIGger:SOURce
- [SOURce<HW>]:BB:WLAD:[TRIGger]:SEQuence
Cloning the Group
// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Wlad.Trigger.Clone();
Direct SCPI Members
- TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:WLAD:TRIGger:RMODe TrigRunModeEnum value = driver.Source.Bb.Wlad.Trigger.Rmode;Queries the current status of signal generation for all trigger modes with IEEE 802.11ad/ay modulation on.
rmode: STOP | RUN
RUN: The signal is generated. A trigger event occurred in the triggered mode.
STOP: The signal is not generated. A trigger event did not occur in the triggered modes, or signal generation was stopped by the command :BB:WLAD:TRIG:ARM:EXECute (armed trigger modes only) .
- int Slength#
// SCPI: [SOURce<HW>]:BB:WLAD:TRIGger:SLENgth int value = driver.Source.Bb.Wlad.Trigger.Slength; driver.Source.Bb.Wlad.Trigger.Slength = 1;Sets the length of the signal sequence to be output in the Single trigger mode (SOUR:BB:WLAD:SEQ SING) . The input is made in terms of samples. It is possible to output just part of the frame, an exact sequence of the frame, or a defined number of repetitions of the frame.
slength: integer
- UnitSlBenum SlUnit#
// SCPI: [SOURce<HW>]:BB:WLAD:TRIGger:SLUNit UnitSlBenum value = driver.Source.Bb.Wlad.Trigger.SlUnit; driver.Source.Bb.Wlad.Trigger.SlUnit = UnitSlBenum.SAMPle;Sets the unit for the entry of the length of the signal sequence (SOUR:BB:WLAD:TRIG:SLEN) to be output in the Single trigger mode (SOUR:BB:WLAD:SEQ SING) .
slUnit: SEQuence | SAMPle
SAMPle: Unit Sample. A single sample is generated after a trigger event.
SEQuence: Unit Sequence Length. A single sequence is generated after a trigger event.
- TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:WLAD:TRIGger:SOURce TrigSourEnum value = driver.Source.Bb.Wlad.Trigger.Source; driver.Source.Bb.Wlad.Trigger.Source = TrigSourEnum.BBSY;Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:
INTernal: Internal manual triggering of the instrument
INTA | INTB: Internal triggering by a signal from the other basebands
External trigger signal via one of the local or global connectors:
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
source: INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 | ELTRigger | INTA | ELCLock | BEXTernal | EXTernal | BBSY
- DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:WLAD:[TRIGger]:SEQuence DmTrigModeEnum value = driver.Source.Bb.Wlad.Trigger.Sequence; driver.Source.Bb.Wlad.Trigger.Sequence = DmTrigModeEnum.AAUTo;Selects the trigger mode.
sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle
AUTO: The modulation signal is generated continuously.
RETRigger: The modulation signal is generated continuously. A trigger event (internal or external) causes a restart.
AAUTo: The modulation signal is generated only when a trigger event occurs. After the trigger event the signal is generated continuously. Signal generation is stopped with command SOUR:BB:WLAD:TRIG:ARM:EXEC and started again when a trigger event occurs.
ARETrigger: The modulation signal is generated only when a trigger event occurs. The device automatically toggles to RETRIG mode. Every subsequent trigger event causes a restart.Signal generation is stopped with command SOUR:BB:WLAD:TRIG:ARM:EXEC and started again when a trigger event occurs.
SINGle: The modulation signal is generated only when a trigger event occurs. Then the signal is generated once to the length specified with command SOUR:BB:WLAD:TRIG:SLEN. Every subsequent trigger event causes a restart.
Subgroups