Source:Bb:W3Gpp:Mstation:Pcpch:Tpc:Read#
SCPI Commands
- [SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:TPC:READ
Direct SCPI Members
- TpcReadModeEnum Get ( )#
- TpcReadModeEnum Get ( MobileStationRepCap mobileStation )
- void Set ( TpcReadModeEnum read )#
- void Set ( TpcReadModeEnum read, MobileStationRepCap mobileStation )
// SCPI: [SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:TPC:READ // Get: TpcReadModeEnum value = driver.Source.Bb.W3Gpp.Mstation.Pcpch.Tpc.Read.Get(); TpcReadModeEnum value = driver.Source.Bb.W3Gpp.Mstation.Pcpch.Tpc.Read.Get(MobileStationRepCap.Default); // Set: driver.Source.Bb.W3Gpp.Mstation.Pcpch.Tpc.Read.Set(TpcReadModeEnum.CONTinuous, MobileStationRepCap.Default); driver.Source.Bb.W3Gpp.Mstation.Pcpch.Tpc.Read.Set(TpcReadModeEnum.CONTinuous);
The command sets the read out mode for the bit pattern of the TPC field of the PCPCH. The bit pattern is selected with the command method RsSmw.Source.Bb.W3Gpp.Mstation.Pcpch.Tpc.Data.Set.
readCONTinuous | S0A | S1A | S01A | S10ACONTinuous: The bit pattern is used cyclically.
S0A: The bit pattern is used once, then the TPC sequence continues with 0 bits.
S1A: The bit pattern is used once, then the TPC sequence continues with 1 bits.
S01A: The bit pattern is used once and then the TPC sequence is continued with 0 and 1 bits alternately (in multiples, depending on by the symbol rate, for example, 00001111) .
S10A: The bit pattern is used once and then the TPC sequence is continued with 1 and 0 bits alternately (in multiples, depending on by the symbol rate, for example, 11110000) .
mobileStationRepeated capability selectorWhen you do not use any explicit repeated capability selector, the value is taken from its parent group.