Source:Bb:W3Gpp:Mstation:Pcpch:SymbolRate#
SCPI Commands
- [SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:SRATe
Direct SCPI Members
- SymbRateEnum Get ( )#
- SymbRateEnum Get ( MobileStationRepCap mobileStation )
- void Set ( SymbRateEnum srate )#
- void Set ( SymbRateEnum srate, MobileStationRepCap mobileStation )
// SCPI: [SOURce<HW>]:BB:W3GPp:MSTation<ST>:PCPCh:SRATe // Get: SymbRateEnum value = driver.Source.Bb.W3Gpp.Mstation.Pcpch.SymbolRate.Get(); SymbRateEnum value = driver.Source.Bb.W3Gpp.Mstation.Pcpch.SymbolRate.Get(MobileStationRepCap.Default); // Set: driver.Source.Bb.W3Gpp.Mstation.Pcpch.SymbolRate.Set(SymbRateEnum.D120k, MobileStationRepCap.Default); driver.Source.Bb.W3Gpp.Mstation.Pcpch.SymbolRate.Set(SymbRateEnum.D120k);
The command sets the symbol rate of the PCPCH. User Equipment 1: When channel coding is active, the symbol rate is limited to the range between 15 and 120 ksps. Values above this limit are automatically set to 120 ksps.
srateD15K | D30K | D60K | D120k | D240k | D480k | D960kmobileStationRepeated capability selectorWhen you do not use any explicit repeated capability selector, the value is taken from its parent group.