Source:Bb:Pramp:Trigger#

SCPI Commands

[SOURce<HW>]:BB:PRAMp:TRIGger:RMODe
[SOURce<HW>]:BB:PRAMp:TRIGger:SLENgth
[SOURce<HW>]:BB:PRAMp:TRIGger:SLUNit
[SOURce<HW>]:BB:PRAMp:TRIGger:SOURce
[SOURce<HW>]:BB:PRAMp:[TRIGger]:SEQuence

Cloning the Group

// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Pramp.Trigger.Clone();

Direct SCPI Members

TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:PRAMp:TRIGger:RMODe
TrigRunModeEnum value = driver.Source.Bb.Pramp.Trigger.Rmode;

Queries the status of signal generation.

rmode: STOP | RUN


int Slength#
// SCPI: [SOURce<HW>]:BB:PRAMp:TRIGger:SLENgth
int value = driver.Source.Bb.Pramp.Trigger.Slength;
driver.Source.Bb.Pramp.Trigger.Slength = 1;

Defines the length of the signal sequence to be output in the SINGle trigger mode, see method RsSmw.Source.Bb.Pramp.Trigger.Sequence.

slength: integer


UnitSlDvbEnum SlUnit#
// SCPI: [SOURce<HW>]:BB:PRAMp:TRIGger:SLUNit
UnitSlDvbEnum value = driver.Source.Bb.Pramp.Trigger.SlUnit;
driver.Source.Bb.Pramp.Trigger.SlUnit = UnitSlDvbEnum.FRAMe;

Defines the unit for the entry of the length of the signal sequence to be output in the Single trigger mode, see method RsSmw.Source.Bb.Pramp.Trigger.Sequence.

slUnit: FRAMe | SEQuence

  • FRAMe: Unit Frame. A single frame is generated after a trigger event.

  • SEQuence: Unit Sequence Length. A single sequence is generated after a trigger event.


TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:PRAMp:TRIGger:SOURce
TrigSourEnum value = driver.Source.Bb.Pramp.Trigger.Source;
driver.Source.Bb.Pramp.Trigger.Source = TrigSourEnum.BBSY;

Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:

  • INTernal: Internal manual triggering of the instrument

  • INTA | INTB: Internal triggering by a signal from the other basebands

  • External trigger signal via one of the local or global connectors:

    • EGT1 | EGT2: External global trigger

    • EGC1 | EGC2: External global clock

    • ELTRigger: External local trigger

    • ELCLock: External local clock

  • For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY

  • OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)

source: INTernal | EGT1 | EXTernal | EGC1 | INTB | OBASeband | ELTRigger | EGT2 | EGC2 | INTA | ELCLock | BEXTernal


DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:PRAMp:[TRIGger]:SEQuence
DmTrigModeEnum value = driver.Source.Bb.Pramp.Trigger.Sequence;
driver.Source.Bb.Pramp.Trigger.Sequence = DmTrigModeEnum.AAUTo;

Selects the trigger mode:

  • AUTO = auto

  • RETRigger = retrigger

  • AAUTo = armed auto

  • ARETrigger = armed retrigger

  • SINGle = single

Selects the trigger mode.

sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle