Source:Bb:Oneweb:Trigger#
SCPI Commands
- [SOURce<HW>]:BB:ONEWeb:TRIGger:RMODe
- [SOURce<HW>]:BB:ONEWeb:TRIGger:SLENgth
- [SOURce<HW>]:BB:ONEWeb:TRIGger:SLUNit
- [SOURce<HW>]:BB:ONEWeb:TRIGger:SOURce
- [SOURce<HW>]:BB:ONEWeb:[TRIGger]:SEQuence
Cloning the Group
// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Oneweb.Trigger.Clone();
Direct SCPI Members
- TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:ONEWeb:TRIGger:RMODe TrigRunModeEnum value = driver.Source.Bb.Oneweb.Trigger.Rmode;Queries the signal generation status.
trigRunMode: STOP | RUN
- int Slength#
// SCPI: [SOURce<HW>]:BB:ONEWeb:TRIGger:SLENgth int value = driver.Source.Bb.Oneweb.Trigger.Slength; driver.Source.Bb.Oneweb.Trigger.Slength = 1;Defines the length of the signal sequence that is output in the SINGle trigger mode.
trigSeqLen: integer
- UnitEnum SlUnit#
// SCPI: [SOURce<HW>]:BB:ONEWeb:TRIGger:SLUNit UnitEnum value = driver.Source.Bb.Oneweb.Trigger.SlUnit; driver.Source.Bb.Oneweb.Trigger.SlUnit = UnitEnum.FRAMe;Defines the unit for the entry of the signal sequence length, generated after the trigger event.
seqLenUnit: SEQuence | FRAMe | SUBFrame | SLOT | SAMPle
FRAMe: Single frame
SEQuence: Single sequence.
SUBFrame: Single subframe.
SLOT: Single slot
SAMPle: Selected number of samples.
- TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:ONEWeb:TRIGger:SOURce TrigSourEnum value = driver.Source.Bb.Oneweb.Trigger.Source; driver.Source.Bb.Oneweb.Trigger.Source = TrigSourEnum.BBSY;Selects the trigger signal source and determines the way the triggering is executed. Provided are:
Internal triggering by a command (INTernal)
External trigger signal via one of the local or global connectors
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
Internal triggering by a signal from the other basebands (INTA | INTB)
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
trigSour: INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 | ELTRigger | INTA | ELCLock | BEXTernal | EXTernal
- DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:ONEWeb:[TRIGger]:SEQuence DmTrigModeEnum value = driver.Source.Bb.Oneweb.Trigger.Sequence; driver.Source.Bb.Oneweb.Trigger.Sequence = DmTrigModeEnum.AAUTo;Selects the trigger mode:
AUTO = auto
RETRigger = retrigger
AAUTo = armed auto
ARETrigger = armed retrigger
SINGle = single
trigMode: AUTO | RETRigger | AAUTo | ARETrigger | SINGle
Subgroups