Source:Bb:Oneweb:Downlink:Pbch#
SCPI Commands
- [SOURce<HW>]:BB:ONEWeb:DL:PBCH:MIB
- [SOURce<HW>]:BB:ONEWeb:DL:PBCH:MSPare
- [SOURce<HW>]:BB:ONEWeb:DL:PBCH:RATBa
- [SOURce<HW>]:BB:ONEWeb:DL:PBCH:SOFFset
- [SOURce<HW>]:BB:ONEWeb:DL:PBCH:SRPeriod
Direct SCPI Members
- bool Mib#
// SCPI: [SOURce<HW>]:BB:ONEWeb:DL:PBCH:MIB bool value = driver.Source.Bb.Oneweb.Downlink.Pbch.Mib; driver.Source.Bb.Oneweb.Downlink.Pbch.Mib = false;Enables transmission of real MIB data.
state: 1 | ON | 0| OFF
- string Mspare#
// SCPI: [SOURce<HW>]:BB:ONEWeb:DL:PBCH:MSPare string value = driver.Source.Bb.Oneweb.Downlink.Pbch.Mspare; driver.Source.Bb.Oneweb.Downlink.Pbch.Mspare = "rawAbc";Sets the 10 spare bits in the PBCH transmission.
mibSpareBits: 64 bit
- double Ratba#
// SCPI: [SOURce<HW>]:BB:ONEWeb:DL:PBCH:RATBa double value = driver.Source.Bb.Oneweb.Downlink.Pbch.Ratba; driver.Source.Bb.Oneweb.Downlink.Pbch.Ratba = 1.0;No help available.
- int Soffset#
// SCPI: [SOURce<HW>]:BB:ONEWeb:DL:PBCH:SOFFset int value = driver.Source.Bb.Oneweb.Downlink.Pbch.Soffset; driver.Source.Bb.Oneweb.Downlink.Pbch.Soffset = 1;Sets an offset for the start value of the SFN (System Frame Number) .
sfnOffset: integer
- PbchSfnRestPeriodEnum SrPeriod#
// SCPI: [SOURce<HW>]:BB:ONEWeb:DL:PBCH:SRPeriod PbchSfnRestPeriodEnum value = driver.Source.Bb.Oneweb.Downlink.Pbch.SrPeriod; driver.Source.Bb.Oneweb.Downlink.Pbch.SrPeriod = PbchSfnRestPeriodEnum.PER3gpp;No help available.