Source:Bb:Gbas:Trigger#
SCPI Commands
- [SOURce<HW>]:BB:GBAS:TRIGger:RMODe
- [SOURce<HW>]:BB:GBAS:TRIGger:SLENgth
- [SOURce<HW>]:BB:GBAS:TRIGger:SLUNit
- [SOURce<HW>]:BB:GBAS:TRIGger:SOURce
- [SOURce<HW>]:BB:GBAS:[TRIGger]:SEQuence
Cloning the Group
// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Gbas.Trigger.Clone();
Direct SCPI Members
- TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:RMODe TrigRunModeEnum value = driver.Source.Bb.Gbas.Trigger.Rmode;Queries the status of signal generation.
rmode: STOP | RUN
- int Slength#
// SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SLENgth int value = driver.Source.Bb.Gbas.Trigger.Slength; driver.Source.Bb.Gbas.Trigger.Slength = 1;Defines the signal sequence length.
slength: integer
- UnitSlBenum SlUnit#
// SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SLUNit UnitSlBenum value = driver.Source.Bb.Gbas.Trigger.SlUnit; driver.Source.Bb.Gbas.Trigger.SlUnit = UnitSlBenum.SAMPle;Sets the units the trigger sequence length is expressed in.
slUnit: SEQuence | SAMPle
- TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:GBAS:TRIGger:SOURce TrigSourEnum value = driver.Source.Bb.Gbas.Trigger.Source; driver.Source.Bb.Gbas.Trigger.Source = TrigSourEnum.BBSY;Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:
INTernal: Internal manual triggering of the instrument
INTA | INTB: Internal triggering by a signal from the other basebands
External trigger signal via one of the local or global connectors:
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
source: INTernal | EGT1 | EXTernal | EGC1 | INTB | OBASeband | ELTRigger | EGT2 | EGC2 | INTA | ELCLock | BEXTernal
- DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:GBAS:[TRIGger]:SEQuence DmTrigModeEnum value = driver.Source.Bb.Gbas.Trigger.Sequence; driver.Source.Bb.Gbas.Trigger.Sequence = DmTrigModeEnum.AAUTo;Selects the trigger mode.
sequence: AUTO | RETRigger | AAUTo | ARETrigger | SINGle
Subgroups