Source:Bb:Evdo:Clipping#

SCPI Commands

[SOURce<HW>]:BB:EVDO:CLIPping:LEVel
[SOURce<HW>]:BB:EVDO:CLIPping:MODE
[SOURce<HW>]:BB:EVDO:CLIPping:STATe

Direct SCPI Members

int Level#
// SCPI: [SOURce<HW>]:BB:EVDO:CLIPping:LEVel
int value = driver.Source.Bb.Evdo.Clipping.Level;
driver.Source.Bb.Evdo.Clipping.Level = 1;

(For reverse link mode only) The command sets the limit for level clipping (Clipping) . This value indicates at what point the signal is clipped. It is specified as a percentage, relative to the highest level. 100% indicates that clipping does not take place. Level clipping is activated with the command SOUR:BB:EVDO:CLIP:STAT ON

level: integer


ClipModeEnum Mode#
// SCPI: [SOURce<HW>]:BB:EVDO:CLIPping:MODE
ClipModeEnum value = driver.Source.Bb.Evdo.Clipping.Mode;
driver.Source.Bb.Evdo.Clipping.Mode = ClipModeEnum.SCALar;

(For reverse link mode only) Sets the method for level clipping.

mode: VECTor | SCALar

  • VECTor: The reference level is the amplitude i+jq

  • SCALar: The reference level is the absolute maximum of the I and Q values.


bool State#
// SCPI: [SOURce<HW>]:BB:EVDO:CLIPping:STATe
bool value = driver.Source.Bb.Evdo.Clipping.State;
driver.Source.Bb.Evdo.Clipping.State = false;

(For reverse link mode only) The command activates level clipping (Clipping) . The value is defined with the commandBB:EVDO:CLIPping:LEVel, the mode of calculation with the command BB:EVDO:CLIPping:MODE.

state: 1 | ON | 0| OFF