Source:Bb:Evdo:Clipping#
SCPI Commands
- [SOURce<HW>]:BB:EVDO:CLIPping:LEVel
- [SOURce<HW>]:BB:EVDO:CLIPping:MODE
- [SOURce<HW>]:BB:EVDO:CLIPping:STATe
Direct SCPI Members
- int Level#
// SCPI: [SOURce<HW>]:BB:EVDO:CLIPping:LEVel int value = driver.Source.Bb.Evdo.Clipping.Level; driver.Source.Bb.Evdo.Clipping.Level = 1;(For reverse link mode only) The command sets the limit for level clipping (Clipping) . This value indicates at what point the signal is clipped. It is specified as a percentage, relative to the highest level. 100% indicates that clipping does not take place. Level clipping is activated with the command SOUR:BB:EVDO:CLIP:STAT ON
level: integer
- ClipModeEnum Mode#
// SCPI: [SOURce<HW>]:BB:EVDO:CLIPping:MODE ClipModeEnum value = driver.Source.Bb.Evdo.Clipping.Mode; driver.Source.Bb.Evdo.Clipping.Mode = ClipModeEnum.SCALar;(For reverse link mode only) Sets the method for level clipping.
mode: VECTor | SCALar
VECTor: The reference level is the amplitude i+jq
SCALar: The reference level is the absolute maximum of the I and Q values.
- bool State#
// SCPI: [SOURce<HW>]:BB:EVDO:CLIPping:STATe bool value = driver.Source.Bb.Evdo.Clipping.State; driver.Source.Bb.Evdo.Clipping.State = false;(For reverse link mode only) The command activates level clipping (Clipping) . The value is defined with the commandBB:EVDO:CLIPping:LEVel, the mode of calculation with the command BB:EVDO:CLIPping:MODE.
state: 1 | ON | 0| OFF