Source:Bb:Evdo#

SCPI Commands

[SOURce<HW>]:BB:EVDO:LINK
[SOURce<HW>]:BB:EVDO:PNOFfset
[SOURce<HW>]:BB:EVDO:PREDefined
[SOURce<HW>]:BB:EVDO:PRESet
[SOURce<HW>]:BB:EVDO:SLENgth
[SOURce<HW>]:BB:EVDO:STATe
[SOURce<HW>]:BB:EVDO:STIMe
[SOURce<HW>]:BB:EVDO:VERSion

Cloning the Group

// Create a clone of the original group, that exists independently
var evdo2 = driver.Source.Bb.Evdo.Clone();

Direct SCPI Members

// SCPI: [SOURce<HW>]:BB:EVDO:LINK
LinkDirEnum value = driver.Source.Bb.Evdo.Link;
driver.Source.Bb.Evdo.Link = LinkDirEnum.DOWN;

Defines the transmission direction.

link: FORWard/DOWN | REVerse/UP


int PnOffset#
// SCPI: [SOURce<HW>]:BB:EVDO:PNOFfset
int value = driver.Source.Bb.Evdo.PnOffset;
driver.Source.Bb.Evdo.PnOffset = 1;

Sets the PN Offset of the 1xEV-DO signal.

pnOffset: integer


EvdoPredSettEnum Predefined#
// SCPI: [SOURce<HW>]:BB:EVDO:PREDefined
EvdoPredSettEnum value = driver.Source.Bb.Evdo.Predefined;
driver.Source.Bb.Evdo.Predefined = EvdoPredSettEnum.ULS1DR153K6;

Sets the UL setting of Terminal 1 to one of the predefined configurations. The predefined settings are made according to 3GPP2 C.S0032-A to allow easy receiver testing. Parameter / Description

  • USER / There are no predefined settings

  • ULS1DR9K6 / UL, Subtype 1, 9.6 kbps.

  • ULS1DR19K2 / UL, Subtype 1, 19.2 kbps.

  • ULS1DR38K4 / UL, Subtype 1, 38.4 kbps.

  • ULS1DR76K8 / UL, Subtype 1, 76.8 kbps.

  • ULS1DR153K6 / UL, Subtype 1, 153.6 kbps.

  • ULS2PS128LL / UL, Subtype 2, 128 bits payload, Low Latency.

  • ULS2PS256HC / UL, Subtype 2, 256 bits payload, High Capacity.

  • ULS2PS256LL / UL, Subtype 2, 256 bits payload, Low Latency.

  • ULS2PS512LL / UL, Subtype 2, 512 bits payload, Low Latency.

  • ULS2PS768LL / UL, Subtype 2, 768 bits payload, Low Latency.

  • ULS2PS1024LL / UL, Subtype 2, 1024 bits payload, Low Latency.

  • ULS2PS1536LL / UL, Subtype 2, 1536 bits payload, Low Latency.

  • ULS2PS2048LL / UL, Subtype 2, 2048 bits payload, Low Latency.

  • ULS2PS3072LL / UL, Subtype 2, 3072 bits payload, Low Latency.

  • ULS2PS4096LL / UL, Subtype 2, 4096 bits payload, Low Latency.

  • ULS2PS6144LL / UL, Subtype 2, 6144 bits payload, Low Latency.

  • ULS2PS8192LL / UL, Subtype 2, 8192 bits payload, Low Latency.

  • ULS2PS12288LL / UL, Subtype 2, 12288 bits payload, Low Latency.

predefined: USER | ULS1DR9K6 | ULS1DR19K2 | ULS1DR38K4 | ULS1DR76K8 | ULS1DR153K6 | ULS2PS128LL | ULS2PS256HC | ULS2PS256LL | ULS2PS512LL | ULS2PS768LL | ULS2PS1024LL | ULS2PS1536LL | ULS2PS2048LL | ULS2PS3072LL | ULS2PS4096LL | ULS2PS6144LL | ULS2PS8192LL | ULS2PS12288LL


void Preset ( )#
void PresetAndWait ( )#
void PresetAndWait ( int opcTimeoutMs )
// SCPI: [SOURce<HW>]:BB:EVDO:PRESet
driver.Source.Bb.Evdo.Preset();
driver.Source.Bb.Evdo.PresetAndWait();
driver.Source.Bb.Evdo.PresetAndWait(1000);

Sets the parameters of the digital standard to their default values (*RST values specified for the commands) . Not affected is the state set with the command SOURce<hw>:BB:EVDO:STATe.

PresetAndWait is the same as Preset, but waits for the operation to complete. The optional entered opcTimeoutMs is only valid for this call. If you omit the opcTimeoutMs, the method uses the settable value RsSmw.Utilities.OpcTimeout.


int Slength#
// SCPI: [SOURce<HW>]:BB:EVDO:SLENgth
int value = driver.Source.Bb.Evdo.Slength;
driver.Source.Bb.Evdo.Slength = 1;

(For reverse link mode only) Sets the sequence length of the arbitrary waveform component of the 1XEV-DO signal in number of frames. This component is calculated in advance and output in the arbitrary waveform generator. It is added to the real time signal components. The number of chips is determined from this sequence length. One slot of 1.67ms duration equals 2048 chips.

slength: integer


bool State#
// SCPI: [SOURce<HW>]:BB:EVDO:STATe
bool value = driver.Source.Bb.Evdo.State;
driver.Source.Bb.Evdo.State = false;

Activates the standard and deactivates all the other digital standards and digital modulation modes in the same path.

state: 1 | ON | 0| OFF


int Stime#
// SCPI: [SOURce<HW>]:BB:EVDO:STIMe
int value = driver.Source.Bb.Evdo.Stime;
driver.Source.Bb.Evdo.Stime = 1;

Sets the System Time value of the 1xEV-DO signal and the base station. The System Time value is expressed in units of 1.67 ms intervals (80 ms/ 48) . Note: In uplink, the value selected for system time must be multiple of 16.

stime: integer


string Version#
// SCPI: [SOURce<HW>]:BB:EVDO:VERSion
string value = driver.Source.Bb.Evdo.Version;

Queries the version of the 1xEV-DO standard underlying the definitions

version: string


Subgroups