Source:Bb:Eutra:Trigger#
SCPI Commands
- [SOURce<HW>]:BB:EUTRa:TRIGger:RMODe
- [SOURce<HW>]:BB:EUTRa:TRIGger:SLENgth
- [SOURce<HW>]:BB:EUTRa:TRIGger:SLUNit
- [SOURce<HW>]:BB:EUTRa:TRIGger:SOURce
- [SOURce<HW>]:BB:EUTRa:[TRIGger]:SEQuence
Cloning the Group
// Create a clone of the original group, that exists independently
var trigger2 = driver.Source.Bb.Eutra.Trigger.Clone();
Direct SCPI Members
- TrigRunModeEnum Rmode#
// SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:RMODe TrigRunModeEnum value = driver.Source.Bb.Eutra.Trigger.Rmode;Queries the signal generation status.
runMode: STOP | RUN
- int Slength#
// SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLENgth int value = driver.Source.Bb.Eutra.Trigger.Slength; driver.Source.Bb.Eutra.Trigger.Slength = 1;Defines the length of the signal sequence that is output in the SINGle trigger mode.
sequenceLength: integer
- UnitEnum SlUnit#
// SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SLUNit UnitEnum value = driver.Source.Bb.Eutra.Trigger.SlUnit; driver.Source.Bb.Eutra.Trigger.SlUnit = UnitEnum.FRAMe;Defines the unit for the entry of the signal sequence length.
seqLenUnit: SEQuence | FRAMe | SUBFrame | SLOT | SAMPle
FRAMe: A single frame is generated after a trigger event.
SEQuence: A single sequence is generated after a trigger event.
SUBFrame: A single subframe is generated after a trigger event.
SLOT: A single slot is generated after a trigger event.
SAMPle: Number of samples are generated after a trigger event.
- TrigSourEnum Source#
// SCPI: [SOURce<HW>]:BB:EUTRa:TRIGger:SOURce TrigSourEnum value = driver.Source.Bb.Eutra.Trigger.Source; driver.Source.Bb.Eutra.Trigger.Source = TrigSourEnum.BBSY;Selects the trigger signal source and determines the way the triggering is executed. Provided are the following trigger sources:
INTernal: Internal manual triggering of the instrument
INTA | INTB: Internal triggering by a signal from the other basebands
External trigger signal via one of the local or global connectors:
EGT1 | EGT2: External global trigger
EGC1 | EGC2: External global clock
ELTRigger: External local trigger
ELCLock: External local clock
For secondary instruments (SCONfiguration:MULTiinstrument:MODE SEC) , triggering via the external baseband synchronization signal of the primary instrument: SOURce1:BB:ARB:TRIGger:SOURce BBSY
OBASeband | BEXTernal | EXTernal: Setting only Provided only for backward compatibility with other Rohde & Schwarz signal generators. The R&S SMW200A accepts these values and maps them automatically as follows: EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB (depending on the current baseband)
source: INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 | ELTRigger | INTA | ELCLock | BEXTernal | EXTernal | BBSY
- DmTrigModeEnum Sequence#
// SCPI: [SOURce<HW>]:BB:EUTRa:[TRIGger]:SEQuence DmTrigModeEnum value = driver.Source.Bb.Eutra.Trigger.Sequence; driver.Source.Bb.Eutra.Trigger.Sequence = DmTrigModeEnum.AAUTo;Selects the trigger mode:
AUTO = auto
RETRigger = retrigger
AAUTo = armed auto
ARETrigger = armed retrigger
SINGle = single
triggerMode: AUTO | RETRigger | AAUTo | ARETrigger | SINGle