Output#
SCPI Commands
- OUTPut<HW>:AMODe
- OUTPut<HW>:IMPedance
Cloning the Group
// Create a clone of the original group, that exists independently
var output2 = driver.Output.Clone();
Direct SCPI Members
- PowAttModeSzuEnum Amode#
// SCPI: OUTPut<HW>:AMODe PowAttModeSzuEnum value = driver.Output.Amode; driver.Output.Amode = PowAttModeSzuEnum.AUTO;Sets the step attenuator mode at the RF output. Note: The setting method RsSmw.Source.Power.Attenuation.RfOff.Mode FATTenuation has higher priority than the attenuator modes FIXed and MANual.
amode: FIXed | MANual | AUTO
AUTO: The step attenuator adjusts the level settings automatically, within the full variation range.
FIXed: The step attenuator and amplifier stages are fixed at the current position, providing level settings with constant output VSWR. The resulting variation range is calculated according to the position.To use this mode, activate the ALC (see [:SOURcehw]:POWer:ALC[:STATe]) .
MANual: You can set the level manually, in 10 dB steps.
- InputImpRfEnum Impedance#
// SCPI: OUTPut<HW>:IMPedance InputImpRfEnum value = driver.Output.Impedance;Queries the impedance of the RF outputs.
impedance: G1K | G50 | G10K