Output:Protection#

SCPI Commands

OUTPut<HW>:PROTection:CLEar
OUTPut<HW>:PROTection:STATe
OUTPut<HW>:PROTection:TRIPped

Direct SCPI Members

void Clear ( )#
void ClearAndWait ( )#
void ClearAndWait ( int opcTimeoutMs )
// SCPI: OUTPut<HW>:PROTection:CLEar
driver.Output.Protection.Clear();
driver.Output.Protection.ClearAndWait();
driver.Output.Protection.ClearAndWait(1000);

Resets the protective circuit after it has been tripped. To define the output state, use the command method RsSmw.Output.State.Value.

ClearAndWait is the same as Clear, but waits for the operation to complete. The optional entered opcTimeoutMs is only valid for this call. If you omit the opcTimeoutMs, the method uses the settable value RsSmw.Utilities.OpcTimeout.


bool State#
// SCPI: OUTPut<HW>:PROTection:STATe
bool value = driver.Output.Protection.State;
driver.Output.Protection.State = false;

Attenuates the RF output signal for about 40 dB to protect external devices against internal signals.

state: 1 | ON | 0| OFF


bool Tripped#
// SCPI: OUTPut<HW>:PROTection:TRIPped
bool value = driver.Output.Protection.Tripped;

Queries the state of the protective circuit.

tripped: 1 | ON | 0| OFF