Source code for RsSmbv.Implementations.Sense.Power.FilterPy.Length.User

from ......Internal.Core import Core
from ......Internal.CommandsGroup import CommandsGroup
from ......Internal import Conversions
from ...... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class UserCls: """User commands group definition. 1 total commands, 0 Subgroups, 1 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("user", core, parent)
[docs] def set(self, user: float, channel=repcap.Channel.Default) -> None: """SCPI: SENSe<CH>:[POWer]:FILTer:LENGth:[USER] \n Snippet: driver.sense.power.filterPy.length.user.set(user = 1.0, channel = repcap.Channel.Default) \n Selects the filter length for SENS:POW:FILT:'TYPE USER. As the filter length works as a multiplier for the time window, a constant filter length results in a constant measurement time (see also 'About the measuring principle, averaging filter, filter length, and achieving stable results') . INTRO_CMD_HELP: The R&S NRP power sensors provide different resolutions for setting the filter length, depending on the used sensor type: \n - Resolution = 1 for R&S NRPxx power sensors - Resolution = 2n for sensors of the R&S NRP-Zxx family, with n = 1 to 16 \n :param user: float Range: 1 to 65536 :param channel: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Sense') """ param = Conversions.decimal_value_to_str(user) channel_cmd_val = self._cmd_group.get_repcap_cmd_value(channel, repcap.Channel) self._core.io.write(f'SENSe{channel_cmd_val}:POWer:FILTer:LENGth:USER {param}')
[docs] def get(self, channel=repcap.Channel.Default) -> float: """SCPI: SENSe<CH>:[POWer]:FILTer:LENGth:[USER] \n Snippet: value: float = driver.sense.power.filterPy.length.user.get(channel = repcap.Channel.Default) \n Selects the filter length for SENS:POW:FILT:'TYPE USER. As the filter length works as a multiplier for the time window, a constant filter length results in a constant measurement time (see also 'About the measuring principle, averaging filter, filter length, and achieving stable results') . INTRO_CMD_HELP: The R&S NRP power sensors provide different resolutions for setting the filter length, depending on the used sensor type: \n - Resolution = 1 for R&S NRPxx power sensors - Resolution = 2n for sensors of the R&S NRP-Zxx family, with n = 1 to 16 \n :param channel: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Sense') :return: user: float Range: 1 to 65536""" channel_cmd_val = self._cmd_group.get_repcap_cmd_value(channel, repcap.Channel) response = self._core.io.query_str(f'SENSe{channel_cmd_val}:POWer:FILTer:LENGth:USER?') return Conversions.str_to_float(response)