SymbolRate
SCPI Commands :
[SOURce]:IQ:OUTPut:DIGital:SRATe:MAX
[SOURce<HW>]:IQ:OUTPut:DIGital:SRATe:SOURce
[SOURce]:IQ:OUTPut:DIGital:SRATe:SUM
[SOURce<HW>]:IQ:OUTPut:DIGital:SRATe
- class SymbolRateCls[source]
SymbolRate commands group definition. 6 total commands, 2 Subgroups, 4 group commands
- get_max() int [source]
# SCPI: [SOURce]:IQ:OUTPut:DIGital:SRATe:MAX value: int = driver.source.iq.output.digital.symbolRate.get_max()
Queries the maximum supported sample rate.
- return
dig_iqhs_in_sr_max: integer Range: 400 to depends on options The maximum value depends on the connected receiving device. For more information, see data sheet.
- get_source() RsSmbv.enums.BboutClocSour [source]
# SCPI: [SOURce<HW>]:IQ:OUTPut:DIGital:SRATe:SOURce value: enums.BboutClocSour = driver.source.iq.output.digital.symbolRate.get_source()
Queries the sample rate source that is a user-defined value.
- return
source: USER User-defined sample rate source
- get_sum() int [source]
# SCPI: [SOURce]:IQ:OUTPut:DIGital:SRATe:SUM value: int = driver.source.iq.output.digital.symbolRate.get_sum()
Queries the maximum supported sample rate.
- return
dig_iqhs_in_sr_sum: integer Range: 400 to depends on options The maximum value depends on the connected receiving device. For more information, see data sheet.
- get_value() float [source]
# SCPI: [SOURce<HW>]:IQ:OUTPut:DIGital:SRATe value: float = driver.source.iq.output.digital.symbolRate.get_value()
Sets the sample rate of the digital I/Q output signal.
- return
srate: float Range: 400 to depends on options, Unit: Hz The maximum value depends on the connected receiving device. For more information, see data sheet.
- set_source(source: RsSmbv.enums.BboutClocSour) None [source]
# SCPI: [SOURce<HW>]:IQ:OUTPut:DIGital:SRATe:SOURce driver.source.iq.output.digital.symbolRate.set_source(source = enums.BboutClocSour.DOUT)
Queries the sample rate source that is a user-defined value.
- param source
USER User-defined sample rate source
- set_value(srate: float) None [source]
# SCPI: [SOURce<HW>]:IQ:OUTPut:DIGital:SRATe driver.source.iq.output.digital.symbolRate.set_value(srate = 1.0)
Sets the sample rate of the digital I/Q output signal.
- param srate
float Range: 400 to depends on options, Unit: Hz The maximum value depends on the connected receiving device. For more information, see data sheet.
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.source.iq.output.digital.symbolRate.clone()