Ndci

SCPI Command :

[SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:CS:NDCI
class NdciCls[source]

Ndci commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(cellNull=CellNull.Default, subframeNull=SubframeNull.Default, userNull=UserNull.Default, bwPartNull=BwPartNull.Default, allocationNull=AllocationNull.Default) int[source]
# SCPI: [SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:CS:NDCI
value: int = driver.source.bb.nr5G.scheduling.cell.subf.user.bwPart.alloc.cs.ndci.get(cellNull = repcap.CellNull.Default, subframeNull = repcap.SubframeNull.Default, userNull = repcap.UserNull.Default, bwPartNull = repcap.BwPartNull.Default, allocationNull = repcap.AllocationNull.Default)

Sets the number of DCIs.

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

param subframeNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)

param userNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)

param bwPartNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘BwPart’)

param allocationNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)

return

num_dci: integer Range: 1 to 4 With R&S SMBVB-K148, the range increases to 32 DCIs.

set(num_dci: int, cellNull=CellNull.Default, subframeNull=SubframeNull.Default, userNull=UserNull.Default, bwPartNull=BwPartNull.Default, allocationNull=AllocationNull.Default) None[source]
# SCPI: [SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:CS:NDCI
driver.source.bb.nr5G.scheduling.cell.subf.user.bwPart.alloc.cs.ndci.set(num_dci = 1, cellNull = repcap.CellNull.Default, subframeNull = repcap.SubframeNull.Default, userNull = repcap.UserNull.Default, bwPartNull = repcap.BwPartNull.Default, allocationNull = repcap.AllocationNull.Default)

Sets the number of DCIs.

param num_dci

integer Range: 1 to 4 With R&S SMBVB-K148, the range increases to 32 DCIs.

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

param subframeNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)

param userNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)

param bwPartNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘BwPart’)

param allocationNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)