Ndci
SCPI Command :
[SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:CS:NDCI
- class NdciCls[source]
Ndci commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(cellNull=CellNull.Default, subframeNull=SubframeNull.Default, userNull=UserNull.Default, bwPartNull=BwPartNull.Default, allocationNull=AllocationNull.Default) int [source]
# SCPI: [SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:CS:NDCI value: int = driver.source.bb.nr5G.scheduling.cell.subf.user.bwPart.alloc.cs.ndci.get(cellNull = repcap.CellNull.Default, subframeNull = repcap.SubframeNull.Default, userNull = repcap.UserNull.Default, bwPartNull = repcap.BwPartNull.Default, allocationNull = repcap.AllocationNull.Default)
Sets the number of DCIs.
- param cellNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- param subframeNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)
- param userNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)
- param bwPartNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘BwPart’)
- param allocationNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)
- return
num_dci: integer Range: 1 to 4 With R&S SMBVB-K148, the range increases to 32 DCIs.
- set(num_dci: int, cellNull=CellNull.Default, subframeNull=SubframeNull.Default, userNull=UserNull.Default, bwPartNull=BwPartNull.Default, allocationNull=AllocationNull.Default) None [source]
# SCPI: [SOURce<HW>]:BB:NR5G:SCHed:CELL<CC(CH0)>:SUBF<SF(ST0)>:USER<US(DIR0)>:BWPart<BWP(GR0)>:ALLoc<AL(USER0)>:CS:NDCI driver.source.bb.nr5G.scheduling.cell.subf.user.bwPart.alloc.cs.ndci.set(num_dci = 1, cellNull = repcap.CellNull.Default, subframeNull = repcap.SubframeNull.Default, userNull = repcap.UserNull.Default, bwPartNull = repcap.BwPartNull.Default, allocationNull = repcap.AllocationNull.Default)
Sets the number of DCIs.
- param num_dci
integer Range: 1 to 4 With R&S SMBVB-K148, the range increases to 32 DCIs.
- param cellNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- param subframeNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Subf’)
- param userNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘User’)
- param bwPartNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘BwPart’)
- param allocationNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Alloc’)