NzpNum
SCPI Command :
[SOURce<HW>]:BB:EUTRa:DL:DRS:CELL<CH0>:NZPNum
- class NzpNumCls[source]
NzpNum commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(cellNull=CellNull.Default) int [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:DL:DRS:CELL<CH0>:NZPNum value: int = driver.source.bb.eutra.downlink.drs.cell.nzpNum.get(cellNull = repcap.CellNull.Default)
Enables up to 96 NonZeroTxPower CSI-RS within the DRS period.
- param cellNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)
- return
num_non_zero_pwr_co: integer Range: 0 to 96
- set(num_non_zero_pwr_co: int, cellNull=CellNull.Default) None [source]
# SCPI: [SOURce<HW>]:BB:EUTRa:DL:DRS:CELL<CH0>:NZPNum driver.source.bb.eutra.downlink.drs.cell.nzpNum.set(num_non_zero_pwr_co = 1, cellNull = repcap.CellNull.Default)
Enables up to 96 NonZeroTxPower CSI-RS within the DRS period.
- param num_non_zero_pwr_co
integer Range: 0 to 96
- param cellNull
optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)