NzpNum

SCPI Command :

[SOURce<HW>]:BB:EUTRa:DL:DRS:CELL<CH0>:NZPNum
class NzpNumCls[source]

NzpNum commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(cellNull=CellNull.Default) int[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:DL:DRS:CELL<CH0>:NZPNum
value: int = driver.source.bb.eutra.downlink.drs.cell.nzpNum.get(cellNull = repcap.CellNull.Default)

Enables up to 96 NonZeroTxPower CSI-RS within the DRS period.

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)

return

num_non_zero_pwr_co: integer Range: 0 to 96

set(num_non_zero_pwr_co: int, cellNull=CellNull.Default) None[source]
# SCPI: [SOURce<HW>]:BB:EUTRa:DL:DRS:CELL<CH0>:NZPNum
driver.source.bb.eutra.downlink.drs.cell.nzpNum.set(num_non_zero_pwr_co = 1, cellNull = repcap.CellNull.Default)

Enables up to 96 NonZeroTxPower CSI-RS within the DRS period.

param num_non_zero_pwr_co

integer Range: 0 to 96

param cellNull

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Cell’)