RsFsw

Contents:

  • Revision History
  • Getting Started
  • Enums
  • RepCaps
  • Examples
  • Instrument API
    • Applications
    • Calculate<Window>
      • DeltaMarker<DeltaMarker>
      • Dline<DisplayLine>
      • Espectrum
      • Feed
      • Fline<FreqLine>
      • FormatPy
      • Iq
      • Limit<LimitIx>
      • Marker<Marker>
        • Aoff
        • Count
        • Function
        • Link
        • LinkTo
        • LoExclude
        • Maximum
        • Minimum
        • Pexcursion
        • Search
        • Spectrogram
        • State
        • Trace
        • X
          • Slimits
            • Left
            • Right
            • State
            • Zoom
          • Ssize
        • Y
        • Z
      • Mask
      • Math
      • Msra
      • Npratio
      • PeakSearch
      • Pline<PowerLine>
      • Pmeter<PowerMeter>
      • Rtms
      • Spectrogram
      • Statistics
      • Threshold
      • Tline<TimeLine>
      • Unit
    • Calibration
    • Configure
    • Diagnostic
    • Display
    • Fetch<Window>
    • FormatPy
    • HardCopy
    • Initiate
    • InputPy<InputPy>
    • Instrument
    • Layout
    • MassMemory
    • Output<OutputConnector>
    • Read
    • Sense
    • Source
    • Status
    • System
    • Trace<Window>
    • Trigger
    • TriggerInvoke
    • Unit
  • Utilities
  • Logger
  • Events
  • Index
RsFsw
  • Instrument API
  • Calculate<Window>
  • Marker<Marker>
  • X
  • Slimits
  • Right
  • View page source

Right

SCPI Command :

CALCulate<n>:MARKer<m>:X:SLIMits:RIGHt
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(window=Window.Default, marker=Marker.Default) → float[source]
# CALCulate<n>:MARKer<m>:X:SLIMits:RIGHt
value: float = driver.calculate.marker.x.slimits.right.get(window = repcap.Window.Default, marker = repcap.Marker.Default)

Defines the right limit of the marker search range for all markers in all windows. If you perform a measurement in the time domain, this command limits the range of the trace to be analyzed.

Parameters:
  • window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

  • marker – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Marker’)

Returns:

limit: The value range depends on the frequency range or sweep time. The unit is Hz for frequency domain measurements and s for time domain measurements. Unit: HZ

set(limit: float, window=Window.Default, marker=Marker.Default) → None[source]
# CALCulate<n>:MARKer<m>:X:SLIMits:RIGHt
driver.calculate.marker.x.slimits.right.set(limit = 1.0, window = repcap.Window.Default, marker = repcap.Marker.Default)

Defines the right limit of the marker search range for all markers in all windows. If you perform a measurement in the time domain, this command limits the range of the trace to be analyzed.

Parameters:
  • limit – The value range depends on the frequency range or sweep time. The unit is Hz for frequency domain measurements and s for time domain measurements. Unit: HZ

  • window – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

  • marker – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Marker’)