RsFsw

Contents:

  • Revision History
  • Getting Started
  • Enums
  • RepCaps
  • Examples
  • RsFsw API Structure
    • Applications
    • Calculate<Window>
      • DeltaMarker<DeltaMarker>
        • Aoff
        • Function
        • LinkTo
        • Maximum
          • Left
          • Next
          • Peak
          • Right
        • Minimum
        • Mode
        • Mref
        • Mreference
        • Spectrogram
        • State
        • Trace
        • X
        • Y
        • Z
      • Dline<DisplayLine>
      • Espectrum
      • Feed
      • Fline<FreqLine>
      • FormatPy
      • Iq
      • Limit<LimitIx>
      • Marker<Marker>
      • Mask
      • Math
      • Msra
      • Npratio
      • PeakSearch
      • Pline<PowerLine>
      • Pmeter<PowerMeter>
      • Rtms
      • Spectrogram
      • Statistics
      • Threshold
      • Tline<TimeLine>
      • Unit
    • Calibration
    • Configure
    • Diagnostic
    • Display
    • Fetch
    • FormatPy
    • HardCopy
    • Initiate
    • InputPy<InputIx>
    • Instrument
    • Layout
    • MassMemory
    • Output<OutputConnector>
    • Read
    • Sense
    • Source
    • Status
    • System
    • Trace<Window>
    • Trigger
    • TriggerInvoke
    • Unit
  • RsFsw Utilities
  • RsFsw Logger
  • RsFsw Events
  • Index
RsFsw
  • »
  • RsFsw API Structure »
  • Calculate<Window> »
  • DeltaMarker<DeltaMarker> »
  • Maximum »
  • Right
  • View page source

Right

SCPI Command :

CALCulate<n>:DELTamarker<m>:MAXimum:RIGHt
class RightCls[source]

Right commands group definition. 1 total commands, 0 Subgroups, 1 group commands

set(window=Window.Default, deltaMarker=DeltaMarker.Default, opc_timeout_ms: int = - 1) → None[source]
# SCPI: CALCulate<n>:DELTamarker<m>:MAXimum:RIGHt
driver.calculate.deltaMarker.maximum.right.set(window = repcap.Window.Default, deltaMarker = repcap.DeltaMarker.Default)

Moves a delta marker to the next positive peak value on the trace. The search includes only measurement values to the right of the current marker position. In the spectrogram, the command moves a marker horizontally to the maximum level in the currently selected frame. The vertical marker position remains the same.

param window

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Calculate’)

param deltaMarker

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘DeltaMarker’)

param opc_timeout_ms

Maximum time to wait in milliseconds, valid only for this call.